Plan Review Notes
Plan Review Notes For Permit 05090878
Permit Number 05090878
Review Stop P
Sequence Number 5
Notes
Date Text
2007-11-03 08:12:57DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1. SHT P-02 ONLY THE FIXTURES WITHIN THE BATHROOM GROUP
 SHALL CONNECT TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. SECTION 909.1. THE BREAKROOM SINK SHALL
 DISCHARGE DOWNSTREAM OF THE BATHROOM FIXTURES. ALSO THE
 FLOOR PLAN DOES NOT REFLECT THE PIPING SHOWN ON THE
 SANITARY RISER DIAGRAM WHICH IS CODE COMPLIANT. PLEASE
 HAVE THE PIPING ON THE FLOOR PLAN REFLECT THE RISER
 DIAGRAM AND COMPLY WITH SECTION 909.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]