| Date |
Text |
| 2006-05-31 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 BUILDING |
| | FBC-2001 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. SHT A-101 LUNCH ROOM SINK SHALL |
| | COMPLY WITH SECTION 11-4.24 AND ALL |
| | SUBSECTIONS. PLEASE PROVIDE A DETAIL |
| | SHOWING COMPLIANCE. CLEAR FLOOR SPACE |
| | SHALL BE FORWARD APPROACH. |
| | ***THE FOLLOWING REQUIREMENTS NOT SHOWN |
| | ON DETAIL: |
| | A. 11-4.24.3 KNEE CLEARANCE |
| | B. 11-4.24.4 SINK DEPTH |
| | C. 11-4.24.7 FAUCETS |
| | |
| | 2. SHT A-105 ACCESSIBILITY DETAILS. SHOW |
| | THE FOLLOWING INFORMATION: |
| | ***THE FOLLOWING REQUIREMENTS NOT SHOWN |
| | AS REQUESTED: |
| | C. 11-4.19.5 FAUCETS |
| | D. 11-4.15.1.3(10)(A) PROVISIONS FOR |
| | THOSE WHO HAVE BENDING OR STOOPING. |
| | |
| | 3. SHT A-105 DOOR SHALL NOT SWING INTO |
| | THE CLEAR FLOOR SPACE REQUIRED FOR ANY |
| | FIXTURE. SECTION 11-4.22.2. DOORS ARE |
| | OPENING INTO THE CLEAR FLOOR SPACE OF |
| | THE DRINKING FOUNTAIN. |
| | ***THE DOORS HAVE BEEN MOVED, BUT STILL |
| | SWING INTO THE CLEAR FLOOR SPACE OF THE |
| | DRINKING FOUNTAIN. (SUGGESTION - REVERSE |
| | THE DOOR SWING AWAY FROM THE DRINKING |
| | FOUNTAIN). |
| | |
| | 4. A-504 DETAIL OF SCUPPER. SHOW HEIGHT |
| | AND WIDTH OF SCUPPER AND IF CIRCULAR |
| | SHOW DIAMETER. MINIMUM 4" OPENING |
| | REQUIRED. ALSO SHOW THE MEASUREMENT OFF |
| | THE ROOF TO THE FLOW LINE. SECTION |
| | 1503.4.2. |
| | ***MEASUREMENT OFF THE ROOF TO THE FLOW |
| | LINE IS NOT SHOWN. |
| | |
| | ***************NEW COMMENT************** |
| | |
| | 1B. SEE ATTACHED SHEET CONCERNING THE |
| | DESIGN PROFESSIONAL AND FS 553.80(2)(B). |
| | THIS IS GIVEN AS A NOTICE ONLY. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |