| Plan Review Notes For Permit 05090663 |
| Permit Number |
05090663 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-09-26 00:00:00 | BUILDING PLAN REVIEW | | | | | | | | | DENIED | | | | | | 1) THE DOOR TO THE COPY/FAX ROOM DOES | | | NOT PROVIDE THE REQUIRED 18" MINIMUM | | | MANEUVERING CLEARANCE ON THE PULL SIDE. | | | SEE FBC 11-4.13.6. | | | | | | 2) ADDRESS COMMENTS OF OTHER PLAN | | | REVIEWERS. | | | | | | 3) SPECIFY THE LOCATION OF THE | | | ACCESSIBLE DRINKING FOUNTAIN. SEE FBC | | | PLUMBING 403.1, 404.2 AND 410. | | | | | | 4) FBC 11-4.1.6(2) ALTERATIONS TO AN | | | AREA CONTAINING A PRIMARY FUNCTION. | | | DUTY TO PROVIDE AN ACCESSIBLE PATH OF | | | TRAVEL TO ALTERED AREAS SHALL BE DEEMED | | | DISPROPORTIONATE TO THE OVERALL | | | ALTERATION WHEN THE COST EXCEEDS 20 % OF | | | THE COST OF THE ALTERATION TO THE | | | PRIMARY FUNCTION AREA. | | | | | | (I) AN ACCESSIBLE ENTRANCE | | | (II) AN ACCESSIBLE ROUTE | | | (III) AT LEAST ONE ACCESSIBLE REST- | | | ROOM FOR EACH SEX OR A SINGLE | | | UNISEX RESTROOM | | | (IIII) ACCESSIBLE TELEPHONE | | | (IV) ELEMENTS SUCH AS PARKING, STOR- | | | AGE OR ALARMS. | | | | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|