| 2006-07-20 00:00:00 | PAUL SCHMITZ |
| | [email protected] |
| | FBC2001 FUEL GAS CODEPLAN REVIEW |
| | FBC 2001 PLUMBING CODEPLAN REVIEW FBC |
| | 2001 FL ACESSIBILITY CODE PLANREVIEW |
| | DENIED "THIRD TIME" |
| | |
| | PREVIOUS NOTE #2 NOT ADDRESSED. |
| | |
| | 104.2 DRAWINGS AND SPECIFICATIONS. |
| | 104.2.1 REQUIREMENTS. AS REQUIRED BY |
| | 104.3.1.1 OF THE CODE, TWO OR MORE |
| | COPIES OF |
| | SPECIFICATIONS, AND OF DRAWINGS DRAWN TO |
| | SCALE WITH SUFFICIENT CLARITY AND DETAIL |
| | TO INDICATE THE |
| | NATURE AND CHARACTER OF THE WORK, SHALL |
| | ACCOMPANY THE APPLICATION FOR A PERMIT. |
| | SUCH |
| | DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF |
| | NOTES OR OTHERWISE, AS TO |
| | THE QUALITY OF MATERIALS, WHERE QUALITY |
| | IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. |
| | SUCH INFORMATION SHALL BE SPECIFIC, AND |
| | THE TECHNICAL CODES SHALL NOT BE CITED |
| | AS A WHOLE OR IN |
| | PART, NOR SHALL THE TERM ?LEGAL? OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR |
| | SPECIFIC INFORMATION. |
| | ALL INFORMATION, DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA |
| | SHALL BEAR THE NAME AND |
| | SIGNATURE OF THE PERSON RESPONSIBLE FOR |
| | THE DESIGN. |
| | |
| | 2)SHT A-1 BREAK ROOM SINKS: |
| | 11-4.24 SINKS. |
| | ?11-4.24.1 GENERAL. SINKS REQUIRED TO |
| | BE ACCESSIBLE BY ?11-4.1 SHALL |
| | COMPLY WITH ?11-4.24. |
| | ?11-4.24.2 HEIGHT. SINKS SHALL BE |
| | MOUNTED WITH THE COUNTER OR RIM NO |
| | HIGHER THAN 34 IN. (865 MM) ABOVE THE |
| | FINISH FLOOR. |
| | ?11-4.24.3 KNEE CLEARANCE. KNEE |
| | CLEARANCE THAT IS AT LEAST 27 IN. (685 |
| | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 |
| | IN (485 MM) DEEP SHALL BE |
| | PROVIDED UNDERNEATH SINKS. |
| | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A |
| | MAXIMUM OF 6-1/2 IN (165 MM) DEEP. |
| | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR |
| | FLOOR SPACE AT LEAST 30 IN. BY 48 |
| | IN. (760 MM BY 1220 MM) COMPLYING WITH |
| | 11-4.2.4 SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD |
| | APPROACH.THE CLEAR FLOOR SPACE SHALL |
| | BE ON AN ACCESSIBLE ROUTE AND SHALL |
| | EXTEND A MAXIMUM OF 19 IN. (485 MM) |
| | UNDERNEATH THE SINK (SEE FIGURE 11-32) |
| | ?11-4.24.6 EXPOSED PIPES AND SURFACES. |
| | HOT WATER AND DRAIN PIPES EXPOSED |
| | UNDER SINKS SHALL BE INSULATED OR |
| | OTHERWISE CONFIGURED SO AS TO PROTECT |
| | AGAINST CONTACT.THERE SHALL BE NO |
| | SHARP OR ABRASIVE SURFACES UNDER SINKS. |
| | ?11-4.24.7 FAUCETS. FAUCETS SHALL |
| | COMPLY WITH ?11-4.27.4.LEVER- |
| | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR |
| | ELECTRONICALLY CONTROLLED MECHANISMS |
| | ARE ACCEPTABLE DESIGNS. |
| | |
| | END OF COMMENTS, QUESTIONS 561-805-6692 |