| 2005-10-08 00:00:00 | PAUL SCHMITZ |
| | FBC 2001 PLUMBING CODE PLAN REVIEW |
| | FBC 2001 CH 11, FL ACESSIBILITY CODE |
| | DENIED |
| | SHT A-1 PROPOSED PLAN |
| | 1)TAB 403.1 DRINKING FOUNTAIN OR A WATER |
| | COOLER REQUIRED.COMPLYING WITH. |
| | SECTION P410, SHOW LOCATION. |
| | DRINKING FOUNTAINS |
| | ?P410.1 APPROVAL. DRINKING FOUNTAINS |
| | SHALL CONFORM TO ASME A112.19.1, |
| | A112.19.2 OR A112.19.9, AND WATER |
| | COOLERS SHALL CONFORM TO ARI 1010. |
| | |
| | 2)SHT A-1 BREAK ROOM SINKS: |
| | 11-4.24 SINKS. |
| | ?11-4.24.1 GENERAL. SINKS REQUIRED TO |
| | BE ACCESSIBLE BY ?11-4.1 SHALL |
| | COMPLY WITH ?11-4.24. |
| | ?11-4.24.2 HEIGHT. SINKS SHALL BE |
| | MOUNTED WITH THE COUNTER OR RIM NO |
| | HIGHER THAN 34 IN. (865 MM) ABOVE THE |
| | FINISH FLOOR. |
| | ?11-4.24.3 KNEE CLEARANCE. KNEE |
| | CLEARANCE THAT IS AT LEAST 27 IN. (685 |
| | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 |
| | IN (485 MM) DEEP SHALL BE |
| | PROVIDED UNDERNEATH SINKS. |
| | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A |
| | MAXIMUM OF 6-1/2 IN (165 MM) DEEP. |
| | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR |
| | FLOOR SPACE AT LEAST 30 IN. BY 48 |
| | IN. (760 MM BY 1220 MM) COMPLYING WITH |
| | 11-4.2.4 SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD |
| | APPROACH.THE CLEAR FLOOR SPACE SHALL |
| | BE ON AN ACCESSIBLE ROUTE AND SHALL |
| | EXTEND A MAXIMUM OF 19 IN. (485 MM) |
| | UNDERNEATH THE SINK (SEE FIGURE 11-32) |
| | ?11-4.24.6 EXPOSED PIPES AND SURFACES. |
| | HOT WATER AND DRAIN PIPES EXPOSED |
| | UNDER SINKS SHALL BE INSULATED OR |
| | OTHERWISE CONFIGURED SO AS TO PROTECT |
| | AGAINST CONTACT.THERE SHALL BE NO |
| | SHARP OR ABRASIVE SURFACES UNDER SINKS. |
| | ?11-4.24.7 FAUCETS. FAUCETS SHALL |
| | COMPLY WITH ?11-4.27.4.LEVER- |
| | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR |
| | ELECTRONICALLY CONTROLLED MECHANISMS |
| | ARE ACCEPTABLE DESIGNS. |
| | END OF COMMENTS, QUESTIONS. |