| Date |
Text |
| 2005-11-06 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2.)PROVIDE INFORMATION IN REGARDS TO |
| | THE BUILDING (SURVEY OR SITE PLAN), |
| | ADJACENT TENANTS IF APPLICABLE.THIS |
| | APPEARS TO BE A FREE STANDING STRUCTURE |
| | WITH ONE SPACE, BUT BUILDING CODE |
| | CLASSIFICATION (ON D1 AND A1) INDICATES |
| | A REQUIREMENT OF 1 HOUR SEPARATION.IS |
| | ANY SEPARATION NECESSARY?THIS SHOULD |
| | BE 2 HOUR FOR FACTORY OCCUPANCY IF IT IS |
| | AN OCCUPANCY SEPARATION, FBC TABLE |
| | 704.1. |
| | |
| | 3.)WHAT DOES THE SOLID SINGLE LINE |
| | ATTACHED TO THE BUILDING REPRESENT?IT |
| | HAS NOT BEEN INCLUDED ON THE WALL |
| | LEGEND.THIS IS ADJACENT TO THE |
| | EXISTING OVERHEAD ELEC SERVICE AND |
| | ANOTHER LINE EXTENDING FROM NEAR THE |
| | EXISTING FIRE SPRINKLER RISER, D1 AND |
| | ALSO APPEARS ON A1.THE EXIT FOR THE |
| | BUILDING OPENS INTO THIS SPACE. |
| | |
| | 4.)D1 SHOWS AN EXISTING OVERHEAD DOOR, |
| | BUT GRAPHICALLY SHOWS LARGE DOUBLE DOORS |
| | WHICH ARE MARKED AS AN EXIT ON A1 AND |
| | A2.PLEASE CLARIFY.FBC1012.1, THE |
| | DOOR WIDTH CANNOT EXCEED 48INCHES. |
| | |
| | 5.)SHOW DIMENSIONS FOR ALL DOORS IN |
| | THE EGRESS PATH. |
| | |
| | 6.)WHAT DOES ETR STAND FOR?THIS NOTE |
| | IS ON SOME OF THE DOORS, A1.IF YOU ARE |
| | GOING TO USE NON STANDARD ABBREVIATIONS, |
| | PLEASE INCLUDE A SCHEDULE TO AVOID |
| | CONFUSION. |
| | |
| | 7.)PROVIDE A MORE COMPLETE PROJECT |
| | DESCRIPTION. |
| | |