Plan Review Notes
Plan Review Notes For Permit 05081995
Permit Number 05081995
Review Stop B
Sequence Number 3
Notes
Date Text
2006-06-07 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 COMMENTS FROM PREVIOUS REVIEW, NUMBERING
 REMAINING THE SAME FOR CONSISTENCY
  
 1.)N/A
  
 2.)ADDRESSED.
  
 3.)THE TOTAL RISER HEIGHT IS 9.25 IN,
 EXCEEDS THE 9IN MAXIMUM HEIGHT
 FBC1009.3(7).
  
 THE RISER HEIGHT WAS NOT CHANGED.THE
 ENGINEER CALLED AND STATED THAT THE
 RISER HEIGHT IS 7 3/4" ON THE PLAN.AS
 I DID NOT HAVE THE PLAN IN FRONT OF ME,
 I TOLD HIM THAT IS ACCEPTABLE.HOWEVER,
 THE RISER HEIGHT IS NOT 7 3/4".THAT
 DIMENSION ON THE PLAN SHOWN FROM GRADE
 TO THE BOTTOM OF THE FIRST TREAD.
 WHEN YOU ADD THE TREAD HEIGHT, 1 1/2",
 THE TOTAL IS 9.25 IN.SEE ATTACHED
 COMMENTARY IN REGARDS TO CORRECT WAY TO
 MEASURE RISER HEIGHT.
  
 4.)A HANDRAIL EXTENSION AT THE BOTTOM
 OF THE STAIR IS REQUIRED, FBC1009.11.5.
  
 NO DIMENSIONS SHOWN.THE EXTENSION IS
 NOT COMPLIANT, PLEASE READ REFERENCED
 CODE SECTION.EXTENSION REQUIRED AT THE
 TOP OF THE FLIGHT ALSO.SEE
 FBC1009.11.5 AND SHOW COMPLIANCE WITH
 ALL DIMENSIONS ON THE PLAN.THE PLAN
 VIEW IS TO MATCH THE ELEVATIONS. NOTE
 THAT THE EXTENSION AS SHOWN GRAPHICALLY
 IS NOT CORRECT BUT ALSO DOES NOT SHOW
 ANY DIMENSIONS.SEE ATTACHED
 COMMENTARY.
  
 5.)N/A
  
 NEW COMMENTS:
  
 6.)LANDING REQUIRED FOR THE STAIR,
 FBC1009.4.
  
 7.)THE TREADS ON AN OPEN TREAD
 STAIRWAY IS TO COMPLY WITH FBC1009.3.2
 EXCEPTION 1 (4" SPHERE).COMMENTARY
 ATTACHED.
  
 8.)SEE ATTACHED FS553.80(2)(B).A 4X
 PLAN REVIEW FEE WILL BE CHARGED IF
 COMMENTS ARE NOT PROPERLY ADDRESSED A
 THIRD TIME.
  
  
  