| Plan Review Notes For Permit 05081995 |
| Permit Number |
05081995 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-03-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)PREVIOUS REVIEW WAS DONE ON | | | FBC2001.THE NEW ENGINEERING DECLARES | | | FBC2004.CONFIRM THAT OTHER SHEETS | | | DECLARE FBC2004, IF APPLICABLE. | | | | | | 3.)THE TOTAL RISER HEIGHT IS 9.25 IN, | | | EXCEEDS THE 9IN MAXIMUM HEIGHT | | | FBC1009.3(7). | | | | | | 4.)A HANDRAIL EXTENSION AT THE BOTTOM | | | OF THE STAIR IS REQUIRED, FBC1009.11.5. | | | | | | 5.)THE PLANS STATE THAT THIS WAS | | | DESIGNED UNDER ASCE7-98, CORRECT | | | STANDARD IS ASCE7-02, FBC35. | | | |
|