| Plan Review Notes For Permit 05081303 |
| Permit Number |
05081303 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-09-16 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED N.O.C. | | | | | | 2- ENERGY CALCS ARE GETTING THE CEILING | | | FAN CREDIT. REVISE ELECTRICAL PLAN TO | | | INCLUDE CEILING FAN SIZE IN ALL ROOMS, | | | INCLUDING THE CEILINGS FANS REQ'D IN THE | | | GREAT ROOM. SEE TABLE 6-6 CHAPTER 13 FBC | | | | | | | | | 3- REVISE ROOF FRAMING PLAN @ ENTRY | | | PORCH ROOF AREA. CONCRETE BEAM DOESN'T | | | GO BACK TO THE FOYER AREA. ALSO, REVISE | | | KNEEWALL ON THE RIGHT HAND SIDE. THERE | | | IS NOT CONCRETE BEAM EITHER. REVISE AS | | | REQUIRED AND SPECIFIY CORRESPONDING | | | CONNECTOR. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 4- REVISE TRUSS ANCHOR SCHEDULE. REVISE | | | NUMBER OF NAILS FOR HUS26. SEE CATALOGUE | | | | | | 5- PROVIDE COMPLETE FLORIDA/LOCAL | | | PRODUCT APPROVAL FOR: | | | A) 1 HR ATRIUM DOOR. NEED INSWING DOOR | | | TO MATCH PLANS. | | | B) ROOF TILE. | | | C) SINGLE HUNG WINDOWS. | | | D) FIXED WINDOWS. | | | E) WINDOW MULLION SPECIFIED AT GREAT | | | ROOM FIXED WINDOWS. | | | | | | 6- SPECIFY MULLION SIZE AND ANCHORS FOR | | | FIXED WINDOWS AT GREAT ROOM. 1X MULLION | | | DOESN'T RESIST THE DESIGN PRESSURES. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|