 FBC2001 FUEL GAS CODEPLAN REVIEW
 FBC 2001 PLUMBING CODEPLAN REVIEW
 FBC 2001 FL ACESSIBILITY CODE PLAN
 REVIEW
 UNSAT, THIRD TIME
  
 PREVIOUS COMMENT (1) NOT ADDRESSED.
 SHT.A-1
  
 (1)SECTION 11-4
 ACCESSIBLE ELEMENTS AND
 SPACES:SCOPE AND TECHNICAL REQUIREMENTS
 ?11-4.1 MINIMUM REQUIREMENTS.
 ?11-4.1.1 APPLICATION.
 ?11-4.1.1(1) GENERAL. THIS CODE
 ESTABLISHES THE MINIMUM STANDARDS FOR
 THE ACCESSIBILITY OF BUILDINGS AND
 FACILITIES BUILT OR ALTERED WITHIN
 THE STATE.
 ?11-4.1.1(1)(A) ALL AREAS OF NEWLY
 DESIGNED OR NEWLY CONSTRUCTED
 BUILDINGS AND FACILITIES REQUIRED
 TO BE ACCESSIBLE BY ?11-4.1.2 AND
 ?11-4.1.3 AND ALTERED PORTIONS OF
 EXISTING BUILDINGS AND FACILITIES
 REQUIRED TO BE ACCESSIBLE BY
 ?11-4.1.6 SHALL COMPLY WITH THIS CODE,
 ?11-4.1 THROUGH ?11-4.35, UNLESS
 OTHERWISE PROVIDED IN THIS
 SECTION OR AS MODIFIED IN A
 SPECIAL APPLICATION SECTION.
  
 (SPECIFICALY) BREAK ROOM SINK
 ?11-4.24 SINKS.
 ?11-4.24.1 GENERAL. SINKS REQUIRED TO
 BE ACCESSIBLE BY ?11-4.1 SHALL
 COMPLY WITH ?11-4.24.
 ?11-4.24.2 HEIGHT. SINKS SHALL BE
 MOUNTED WITH THE COUNTER OR RIM NO
 HIGHER THAN 34 IN. (865 MM) ABOVE THE
 FINISH FLOOR.
 ?11-4.24.3 KNEE CLEARANCE. KNEE
 CLEARANCE THAT IS AT LEAST 27 IN. (685
 MM) HIGH, 30 IN. (760 MM) WIDE, AND 19
 IN (485 MM) DEEP SHALL BE
 PROVIDED UNDERNEATH SINKS.
 ?11-4.24.4 DEPTH. EACH SINK SHALL BE A
 MAXIMUM OF 6-1/2 IN (165 MM)
 DEEP.
 ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR
 FLOOR SPACE AT LEAST 30 IN. BY 48
 IN. (760 MM BY 1220 MM) COMPLYING WITH
 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A SINK TO ALLOW FORWARD
 APPROACH.THE CLEAR FLOOR SPACE SHALL
 BE ON AN ACCESSIBLE ROUTE AND SHALL
 EXTEND A MAXIMUM OF 19 IN. (485 MM)
 UNDERNEATH THE SINK (SEE FIGURE
 11-32).
 ?11-4.24.6 EXPOSED PIPES AND SURFACES.
 HOT WATER AND DRAIN PIPES EXPOSED
 UNDER SINKS SHALL BE INSULATED OR
 OTHERWISE CONFIGURED SO AS TO PROTECT
 AGAINST CONTACT.THERE SHALL BE NO
 SHARP OR ABRASIVE SURFACES UNDER
 SINKS.
 ?11-4.24.7 FAUCETS. FAUCETS SHALL
 COMPLY WITH ?11-4.27.4.LEVER-
 OPERATED, PUSH-TYPE, TOUCH-TYPE, OR
 ELECTRONICALLY CONTROLLED MECHANISMS
 ARE ACCEPTABLE DESIGNS.
  
 PROVIDE A ELEVATION DRAWING SHOWING
 COMPLIANCE WITH ABOVE COMMENTS. A FOWARD
 APPROACH, NO DOORS ON CABNET.
  
 END OF COMMENTS, QUESTIONS 561-805-6691