| Date |
Text |
| 2005-08-31 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE STAMPED |
| | AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION.561-233-5025 |
| | |
| | 3.)INTERIOR FINISH CLASSIFICATION IN |
| | GENERAL NOTES IS FOR F OCCUPANCY.YOU |
| | HAVE DECLARED B OCCUPANCY IN GENERAL |
| | CODE INFORMATION.PLEASE CLARIFY. |
| | |
| | 4.)PROVIDE DESIGN LOAD INFORMATION FOR |
| | THE MEZZANINE, FBC TABLE 1604.1.WHAT |
| | WILL BE STORED HERE? |
| | |
| | 5.)ENERGY CALCS REQUIRED, FBC13. |
| | |
| | 6.)DECLARE AN OCCUPANT LOAD FOR THE |
| | MEZZANINE. |
| | |
| | 7.)THE SINK IN THE MEZZANINE IS TO |
| | COMPLY WITH FBC11-4.24.1 THROUGH |
| | 11-4.24.7.PROVIDE COMPLIANT DETAILS. |
| | |
| | 8.)THE DOOR SWINGS INTO THE CLEAR |
| | FLOOR SPACE FOR THE SINK, FBC11-4.24.5. |
| | |
| | 9.)SHOW TURNING RADIUS IN THE |
| | MEZZANINE BATHROOM, FBC11-4.22.3. |
| | |
| | 10.)PROVIDE ACCESSIBLE LAV DETAILS FOR |
| | THE MEZZANINE BATHROOM, FBC11-4.19. |
| | |
| | 11.)GRAB BARS REQUIRED IN MEZZANINE |
| | BATHROOM, FBC11 FIGURE 29. |
| | |
| | 12.)PROVIDE A DETAIL FOR THE SHOWER TO |
| | COMPLY WITH FBC11-4.21. |
| | |
| | 13.)PROVIDE A HEIGHT FOR DETAIL C-A9. |
| | |
| | 14.)PROVIDE FIRE SPRINKLER PLANS FOR |
| | THE MEZZANINE.THIS IS DECLARED AS A |
| | FULLY SPRINKLED BUILDING. |
| | |