| 2005-09-01 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05080524 |
| | ADD: 5800 CORPORATE WAY |
| | CONT:LTL BUILDERS |
| | TEL: (561)628-9753 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RD REVIEW |
| | ACTION: DENIED |
| | |
| | 1)COMMENT 4B FROM THE PREVIOUS EVIEW |
| | DEALS WITH THE "DESIGN OCCUPANT |
| | LOAD".THIS IS DIFFERENT FORM THE |
| | CALCULATED LOAD. THE DESIGN OCCUPANT |
| | LOAD THE DESIGNER PUTS THIS RESTRICTION |
| | ON THE BUILDING AND WILL PRINT OUT ON |
| | THE C.O.THE PLANS STATE ACUALL |
| | OCCUPANT LOAD TO BE 99. |
| | |
| | 2) COMMENT 4B ALSO INDICATES THE MINIMUM |
| | |
| | CORRIDOR WIDTH OF 44". THIS IS TAKING |
| | THE EXEMPTION FOR EDUCATIONAL |
| | OCCUPANCIES SERVICING LESS THAN 100. |
| | WHERE YOU INDICATE THE EXEMPTION UNDER |
| | 1016.2 EXCEPTION(2). YOU LOOK AT THE A |
| | GENERAL REQUIREMENT AND A SPECIFIC |
| | REQUIREMENT, THE SPECIFIC REQUIREMEENT |
| | SHALL BE APPLICABLE. THE GENERAL |
| | REQUIREMENT IS 44" THE MORE STRICTIVE IS |
| | |
| | EDUCATIONAL WILL CORRIDORS OF 72" IF 100 |
| | OR MORE PERSONS ARE UNDER THIS |
| | EDUCATIONAL OCCUPANCY. |
| | |
| | 3) A FIRE SPRINKLER PERMIT IS DROPPED |
| | OFF, NO FEES WERE PAID, NO PLANS |
| | SUBMITTED INDICATING THE 19 HEADS THAT |
| | WERE ADDED, ALSO NO CALCULATIONS |
| | PROVIDED. |
| | |
| | 4) THE APPLICATION FOR THE FIRE VARIANCE |
| | TO BE SUBMITTED BEFORE THIS COMMENT WILL |
| | NOT REAPPEAR |
| | |
| | BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |