2005-08-10 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05080524
 ADD: 5800 CORPORATE WAY
 CONT:LTL BUILDERS
 TEL: (561)628-9753
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) PLANS INDICATE DESIGN TO FL BLDG CODE
 2001, IT WAS AGREED ON THAT THE DESIGN
 CRITERIA WOULD BE TO THE FL 2004 CODE.
 THE 2004 CODE WILL PROVIDE THE DESIGNER
 GREATER LATITUDES IN SESIGN.
  
 3) UNDER THE 2004 CODE REVISIT THE
 MINIMUM BLDG TYPE FOR DESIGN.TABLE 503.
  
 4A) SEE 110.1.2* REQUIREMENTS FOR
 CERTIFICATE OF OCCUPANCY SEE ITEMS 1-12.
  
 4B) NOTE ITEM# 10 ON THE REQUIREMENTS
 FOR C. O. "THE DESIGN OCCUPANT LOAD".!!!
 THIS LIMITATION UNDER 1004.1.1 WILL
 ALLOW THE DESIGNER TO "LIMIT THE DESIGN
 LOAD". UNDER THIS EDITION OF THE CODE
 SEE SECTION 1016.2 CORRIDOR WIDTHS,
 MINIMUM CORRIDOR WIDTH SHALL BE AS
 DETERMINED IN 1005.1 BUT NOT LESS THAN
 44" SEE EXCEPTIONS (4) 72" IN GROUP "E"
 WITH A OCCUPANT LOAD GREATER THAN 100,
 THE CORRIDOR WIDTHCAN BE 44" IF THE
 DESIGNER LIMITS THE OCCUPANT LOAD UNDER
 100, EVEN THOUGH THE TOTAL SHOWN ON THE
 PLAN IS GREATER THAN 100. CORRECT PLAN
 TO REFLECT THE NEW "DESIGN OCCUPANT
 LOAD".
  
 4C) INDICATE COMPLIANCE WITH CORRIDORS
 WITH TABLE 1016.1 WITH FIRE SPRINKLERS
 FOR WALLS AND DOORS.SEE FOOTNOTE "C".
  
 5)THE COPY ROOM DOOR WILL NOT MAKE THE
 ACCESSIBILITY REQUIREMENTS 11-4.13.6
 REQUIRING THE 18" ON THE PULL SIDE OF
 LATCH.
  
 6) PLANS INDICATE A STORAGE AREA THAT
 COMMUNICATES WITH THE EXIT ACCESS
 CORRIDOR, NO SEPERATION?
  
 7) AIR MOVEMENT IN CORRIDORS 1016.4.
 PROVIDE COMPLIANCE WITH EXIT ACCESS
 CORRIDORS SHALL NOT SERVE AS SUPPLY,
 RETURN, EXHAUST RELIEF OR VENTILATION
 AIR DUCTS, SEE EXCEPTIONS.
  
 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.