2005-08-30 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05080369
 ADD: 2501 S FLAGLER DR
 CONT: ANSCHNETZ ALUMINUM
 TEL: (954)868-2266
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1) REQUIRES TESTING TO ASTM D5034-95
 BREAKING STRENGTH & ELONGATION OF
 TEXTILE FABRICS:
  
 424.2.17.1.15(2)
 2. THE MESH UTILIZED IN THE BARRIER
 SHALL HAVE A MINIMUM TENSILE
 STRENGTH ACCORDING TO ASTM
 D5034-95 OF 100 LBF., AND A MINIMUM
 BALL BURST STRENGTH ACCORDING
 TO ASTM D3787-89 OF 150 LBF.THE
 MESH SHALL NOT BE CAPABLE OF
 DEFORMATION SUCH THAT A 1/4" ROUND
 OBJECT COULD PASS THROUGH THE
 MESH.THE MESH SHALL RECEIVE A
 RATING OF "NO DISCOLORATION"
 WHEN TESTED ACCORDING TO ASTM G53-96
 (WEATHERABILITY, 1200 HOURS.)
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715