| Plan Review Notes For Permit 05080279 |
| Permit Number |
05080279 |
|
| Review Stop |
M |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-09-16 00:00:00 | BUILDING #5 DENIED | | | APT.101,102,103 | | | | | | 1) PLEASE REFER TO SECTION 401.5.1 | | | INTAKE OPENING.FRESH AIR MUST BE 10 FT. | | | FROM DOORS AND WINDOWS FBC(M)2001 | | | 2) PLEASE REFER TO SECTION 504.6 CLOTHES | | | DRYER DUCT. DEVELOPED DUCT LENGTH GRATER | | | THAN 25 FT.FBC(M)2001 | | | 3) PLEASE REFER TO SECTION 601.4 | | | BALANCED RETURN AIR.TRANSFER DUCT IN | | | MASTER BEDROOM IS TO SMALL.FBC(M)2001 | | | 4) PLEASE REFER TO SECTION | | | 301.14.FBC(M)2001 | | | | | | APT.201,203 | | | 1) PLEASE REFER TO SECTION 601.4 | | | EXCEPTION #3 BALANCED RETURN AIR | | | TRANSFER DUCT IS NOT REQUIRED IN UTILITY | | | ROOM.FBC(M)2001 | | | 2) PLEASE REFER TO SECTION 606.2.1 | | | SUPPLY AIR SYSTEMS.FOR FAN SHUTDOWN. | | | 3) PLEASE REFER TO SECTION 606.4.1 | | | SUPERVISION FBC(M)2001. | | | 4) PLEESE REFER TO SECTION 601.14 FLOOD | | | HAZAED. FBC(M) 2001 | | | | | | APT.202 | | | PLEASE REFER TO SECTION 601.4 BALANCED | | | RETURN AIR EXCEPTION #3.TRANSFER DUCT IS | | | NOT REQUIREDIN UTILITY ROOM FBC(M)2001 | | | 2) PLEASE REFER TO SECTION 301.14 FLOOD | | | HAZAER.FBC(M 2001 | | | 3) PLEASE REFER TO SECTION 401.5.1 | | | INTAKE OPENING. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|