2005-08-19 00:00:00DENIED
  
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE DISTANCE FROM THE ADDITION TO THE
 PROPERTY LINE IS ILLEGIBLE ON THE SITE
 PLAN. THIS IS REQUIRED TO DETERMINE THE
 PERCENTAGE OF WALL AREA ALLOWED AS
 OPENINGS. IF THE DISTANCE IS OVER 10' TO
 20' THE AMOUNT OF WALL AREA ALLOWED AS
 OPENINGS IS 40 PERCENT.
  
 4) PROVIDE ELEVATIONS OF THE STRUCTURE.
 SPECIFY THE ROOF PITCH AND THE MEAN ROOF
 HEIGHT.
  
 5) SPECIFY THE SIZE OF THE THREE REBARS
 IN THE STEM WALL FOOTING.
  
 6) FL. BLD CODE 1606.1.7 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 7) SPECIFY THE WINDLOAD PRESSURES AT THE
 EXTERIOR OPENINGS.
  
 8) PROVIDE A ROOF FRAMING PLAN AND A
 TRUSS ANCHOR SCHEDULE.
  
 9) SPECIFY THE CEILING AND INTERIOR WALL
 FINISHES. SPECIFY THE EXTERIOR WALL AND
 SOFFIT MATERIALS.
  
 10) SPECIFY THE ATTIC AND WALL
 INSULATION.
  
 11) SUBMIT ENERGY CALCULATIONS.
  
 12) SPECIFY ATTIC VENTILATION PER FBC
 2309.7.
  
 13) SPECIFY THE ROOF SHEATHING MATERIAL
 AND FASTENER TYPE AND SPACING. SEE CITY
 OF WPB AMENDMENTS TO FBC TABLES 2306.1
 AND 2307.6B.
  
 14) PRODUCT APPROVALS SUBMITTED
 WITH PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT WWW.FLORIDABUILDING.ORG. PRODUCTS
 WITH STATEWIDE APPROVAL ARE REQUIRED TO
 BE SUBMITTED WITH A COVER SHEET THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM
 THE STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
 SUBMIT STATE OR LOCAL PRODUCT APPROVALS
 (COVER SHEET AND NOA OR OTHER
 EVAUALUATION WITH INSTALLATION
 INSTRUCTIONS) FOR WINDOWS, MULLIONS,
 STORM PANELS, ROOFING MATERIALS AND
 TRUSS CONNECTORS.
  
 15) ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN PER
 CITY AMENDMENTS TO FBC 104.2.1.
  
 16)FBC 1606.1.4 REQUIRES IMPACT
 PROTECTION FOR GLAZED OPENINGS. SUBMIT
 TWO SETS OF KEY PLANS AND INSTALLATION
 SCHEDULES FOR THE STORM PANELS. SPECIFY
 THE MOUNT TYPE, FASTENER TYPE AND
 FASTENER SPACING.
  
 17) IN ORDER TO REUSE THE EXISTING
 WINDOWS, STATE OR LOCAL PRODUCT
 APPROVALS FOR THEM IS REQUIRED TO BE
 SUBMITTED.
  
 18) ADDITIONAL COMMENTS MAY RESULT WHEN
 THE ADDITIONAL INFORMATION REQUESTED
 ABOVE IS SUBMITTED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  