| Date |
Text |
| 2005-08-30 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)PROVIDE A SURVEY AND SITE PLAN. |
| | |
| | 2.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE STAMPED |
| | AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION.561-233-5025 |
| | |
| | 3.)THERE ARE TWO DIFFERENT SHEET A2-1, |
| | BOTH SHOWING A FLOOR PLAN.I HAVE |
| | REVIEWED THE FLOOR PLAN ON THE SHEET |
| | WITH THE FURNITURE PLAN BECAUSE IT |
| | CONTAINS INFORMATION NOT ON THE OTHER |
| | SHEET.PLEASE INCORPORATE THE DETAILS |
| | ON THE OTHER A2-1 INTO THIS SHEET, AND |
| | ONLY INCLUDE ONE FLOOR PLAN/FURNITURE |
| | PLAN. |
| | |
| | 4.)COMBUSTIBLES IN CONCEALED SPACES |
| | NOT ALLOWED IN TYPE IV CONSTRUCTION, |
| | FBC707.1; SEE THE WINDOW BUCK DETAIL, |
| | DOOR FRAMING. |
| | |
| | 5.)SHOW MANEUVERING CLEARANCE FOR PULL |
| | SIDE OF DOORS, FBC11 FIGURE 25, |
| | FBC11-4.13.6.MANY DOORS APPEAR |
| | NONCOMPLIANT. |
| | |
| | 6.)THE FURNITURE PLAN APPEARS TO BE |
| | THE SAME AS THE FLOOR PLANS.TO AVOID |
| | CONFUSION AND TO MAINTAIN CONSISTENCY, |
| | PLEASE SUPPLY ONE FURNITURE PLAN. |
| | |
| | 7.)SHOW THE ACCESSIBLE ROUTE, |
| | FBC11-4.1.2.IT IS NOT CLEAR WHICH |
| | DOORS ARE ACCESSIBLE ENTRANCES AND |
| | EXITS. |
| | |
| | 8.)PROVIDE A DETAIL FOR THE HANDRAIL |
| | FOR THE STAIRS, FBC11-4.94, FIGURE |
| | 11-19. |
| | |
| | 9.)THE RAMP IS TO COMPLY WITH |
| | FBC11-4.8.PLEASE SEE: |
| | |
| | A.)11-4.8.6, CROSS SLOPE IS NOT TO |
| | EXCEED 1:50.1:12 IS SHOWN. |
| | |
| | B.)11-4.8.2, THE SLOPE IS TO BE 1 TO |
| | 12 MAXIMUM.PROVIDE A DETAIL SHOWING |
| | ELEVATION CHANGES SO THAT CODE |
| | COMPLIANCE CAN BE DETERMINED. |
| | |
| | C.)11-4.8.4(3), THE MINIMUM LANDING |
| | SIZE IS TO BE 60 X 60 WHERE THE RAMP |
| | CHANGES DIRECTION. |
| | |
| | D.)11-4.8.4(1) THROUGH (4), SHOW |
| | COMPLIANCE WITH DIMENSIONS. |
| | |
| | 10.)PROVIDE A DETAIL FOR THE HANDRAIL, |
| | FBC11-4.8.5.SHOW REQUIRED EXTENSIONS. |
| | |
| | 11.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |