2005-10-05 00:00:00DENIED
  
 1) THE ARCHED FIXED GLASS WINDOW IN THE
 MASTER BATH IS 42 SQFT (6' X 7'). THE
 LARGEST AREA ALLOWED BY THE PRODUCT
 APPROVAL SUBMITTED IS 32 SQFT.
  
 2) THE NOTE ON A1 OF THE PLANS FOR THE
 TRANSOM ABOVE THE GREAT ROOM FRENCH
 DOORS SPECIFIES NOA 03-0508.01. THIS
 WINDOW IS SMALL MISSLE IMPACT RATED ONLY
 AND IS REQUIRED TO BE SHUTTERED IF BELOW
 30 FEET. REVISE PLANS IF LARGE MISSLE
 IMPACT IS DESIRED.
  
 3) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 ANCHOR BOLTS FOR THE BEAM HANGER IN
 DETAIL R ON A6.
  