| Plan Review Notes For Permit 05080148 |
| Permit Number |
05080148 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-08-24 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE TRUSS CONNECTOR LOCATIONS | | | ON THE ROOF FRAMING PLAN FOR THE | | | CONNECTORS LISTED IN THE ANCHOR SCHEDULE | | | ON A3. | | | | | | 3) TRUSS ANCHOR NOTE G REFERS TO DETAIL | | | D6 ON PAGE A6. THAT DETAIL IS A TYPICAL | | | WALL SECTION. PLEASE CORRECT. | | | | | | 4) THE ARCHED FIXED GLASS WINDOW IN THE | | | MASTER BATH IS 42 SQFT (6'X 7') AND THE | | | LARGEST WINDOW IN THE PRODUCT APPROVAL | | | IS 32 SQFT. SUBMIT APPROPRIATE PRODUCT | | | APPROVAL. | | | | | | 5) THE NOTE ON A1 FOR THE TRANSOM ABOVE | | | THE GREAT ROOM FRENCH DOORS SPECIFIES | | | NOA 03-0508.01. THIS PRODUCT APPROVAL | | | WAS NOT SUBMITTED. PLEASE CORRECT. | | | | | | 6) SPECIFY THE CONNECTIONS OF THE PORCH | | | GIRDERS AND ENTRY PORCH BEAMS AT | | | EXTERIOR MASONRY WALLS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|