| Date |
Text |
| 2005-08-28 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05080077 |
| | ADD: 524 19TH ST UNIT A, B, C & D |
| | CONT: W. P. B. HOUSING AUTHORITY |
| | TEL: (561)719-2217 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) NALYWAJKO & ASSOCIATES SUBMITTALS ARE |
| | COPIES AND NO RAISED SEAL NOR ORIGINAL |
| | SIGNATURES. |
| | PLANS, SPECIFICATIONS,REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | 2) THERE APPEARS TO BE (2) STRUCURAL |
| | ENGINEERS ON THIS JOB, THE ABOVE |
| | MENTINED, & REDDY CHUNDI PLEASE EXPLAIN? |
| | |
| | 3) PROVIDE THE FOLOWWING INFORMATION: |
| | 601.2.1 EVERY BUILDING SHALL BE |
| | CLASSIFIED BY THE BUILDING OFFICIAL |
| | INTO ONE OF THE TYPES OF CONSTRUCTION AS |
| | SET FORTH IN THIS SECTION. |
| | |
| | TYPE ITYPE V |
| | TYPE II1-HOUR PROTECTED |
| | TYPE IIIUNPROTECTED |
| | TYPE IV TYPE VI |
| | 1-HOUR PROTECTED1-HOUR PROTECTED |
| | UNPROTECTED UNPROTECTED |
| | ALSO PROVIDE HOW MANY STORIES, SQ FT PER |
| | FLOOR, AND IF FIRE SPRINKLERED? |
| | |
| | 4) THE 81/2X 11 NALYWAJKO PLAN DOESN'T |
| | INDICATE THE STRAPPING FOR THE |
| | INDIVIDUAL STUDS? |
| | NOR DOES THE DETAIL INDICATE THE TYPE |
| | OF SUBSHEATHING OR FINISH MATERIAL. |
| | THE THIRD ITEM MISSING ON THIS SAME |
| | DETAIL IS THE WEATHERPROOFING OF THE |
| | BOTTOM PLATE- NO WATER INTRUSION INTO |
| | THE HABITABLE SPACE. |
| | |
| | 5) PROVIDE THE WINDOW SIZE FOR THE |
| | BEDROOM WINDOWS, PRODUCT APPROVALS |
| | SUBMITTED INDICATE CASEMENT PROVIDE THE |
| | CLEAR AREA FOR BEDROOM WINDOWS. |
| | |
| | 6)THE REPORT SUBMITTED FOR PGT CASEMENT |
| | WINDOWS WITH THE FL# 245 INDICATES THE |
| | 2001 CODE WHILE ON LINE THE REPORT READS |
| | 2004? |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |