Plan Review Notes
Plan Review Notes For Permit 05080017
Permit Number 05080017
Review Stop P
Sequence Number 1
Notes
Date Text
2005-08-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1. SUBMIT A DETAIL FOR TOILET ROOMS
 SHOWING COMPLIANCE WITH THE FOLLOWING:
 FOR W/C'S
 A. 11-4.16.2 CLEAR FLOOR SPACE
 B. 11-4.16.3 HEIGHT
 C. 11-4.16.4 GRAB BARS
 D. 11-4.16.5 FLUSH CONTROLS
 E. 11-4.16.6 DISPENSERS
 W/C'S TO BE 18" OFF WALL TO CENTERLINE
 OF FIXTURE, AND LAVS TO BE MIN. 15" OFF
 WALL TO CENTERLINE OF FIXTURE. FIG. 28.
 FOR LAVS
 A. 11-4.19.2 HEIGHT & CLEARANCES
 B. 11-4.19.3 CLEAR FLOOR SPACE
 C. 11-4.19.4 EXPOSED PIPES AND SURFACES
 D. 11-4.19.5 FAUCETS
 2. SHT A-1 DETAIL #4 SHOW THE FOLLOWING:
 A. 11-4.24.4 SINK DEPTH
 B. 11-4.24.5 CLEAR FLOOR SPACE
 C. 11-4.24.6 EXPOSED PIPES AND SURFACES
 D. 11-4.24.7 FAUCETS
 3. PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED.- SUBMIT A DETAIL FOR
 DRINKING FOUNTAIN SHOWING COMPLIANCE
 WITH SECTIONS 11-4.1.3(10)(A)
 (PROVISIONS FOR THOSE WHO HAVE
 DIFFICULTY BENDING OR STOOPING), AND
 11-4.15 AND ALL SUBSECTIONS.
 4. SHT P-1 SANT. RISER DIAGRAM. SECTION
 909.1 ONLY THE FIXTURES WITHIN THE
 BATHROOM GROUPS SHALL CONNECT TO THE
 WET-VENTED HORIZONTAL BRANCH DRAIN. ANY
 ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT. SECTION
 909.1 -NEW SINKS SHALL CONNECT TO THE
 BLDG DRAIN DOWNSTREAM OF THE BATHROOM
 FIXTURES.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]