| Plan Review Notes For Permit 05071036 |
| Permit Number |
05071036 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2005-09-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05071036 | | | ADD: 7203 TRADITION COVE LN W. | | | CONT: VAN KIRK & SONS | | | TEL: (954)755-4402 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | POOL REVIEW | | | ACTION: REVIEWED | | | | | | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. | | | BUILDING PLAN REVIEW | | | PERMIT: 05071036 | | | ADD: 7203 TRADITION COVE | | | CONT: VAN KIRK & SONS | | | TEL: (954)4402 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | | | | 1)COMMENT NUMBER 2 FROM THE PREVIOUS | | | REVIEW. MISSING THE LAYOUT SHEET OF THE | | | POOL. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|