| 2006-01-27 00:00:00 | 1) THE BUILDING FOOTPRINT AND POOL DECK |
| | DOES NOT MATCH THOSE APPROVED BY ORD. |
| | NO. 3804-04.PROVIDE A PLAN SHOWING THE |
| | DIFFERENCES.DEPENDING ON THE SCALE OF |
| | THE CHANGES, EITHER A MINOR OR MAJOR |
| | AMENDMENT WILL BE REQUIRED. |
| | |
| | 2) PARKING DETAILS FOR REGULAR, COMPACT |
| | AND DISABLED SPACES ARE REQUIRED. |
| | |
| | 3) ALL DRIVE AISLES HAVING 90 DEGREE |
| | PARKING STALLS REQUIRE A 24 FOOT WIDTH. |
| | THIS STANDARD IS NOT MET ON THE NORTHERN |
| | AND WESTERN MOST PARKING AISLES ON |
| | LEVELS 1, 2 AND 3 AND THE EASTERNMOST |
| | AISLES ON LEVELS 2 AND 3. |
| | |
| | 4) COMPACT SPACES SHALL BE CLEARLY |
| | MARKED ON ALL SHEETS. |
| | |
| | 5) THE PARKING SPACE LABELS/COUNTS ON |
| | SHEET A1.02 ARE INCORRECT AND |
| | MISLABELED. |
| | |
| | 6) SUPPORT COLUMNS MAY NOT BE LOCATED IN |
| | THE DOUBLE STRIPED AREA ON BOTH SIDES OF |
| | A REGULAR SPACE AS THIS RENDERS THE |
| | SPACE TOO NARROW TO PROVIDE ADEQUATE |
| | TURNING RADIUS. |
| | |
| | 7) THE SPACE LABELS AS 1-233 DOES NOT |
| | ALLOW FOR ADEQUATE TURN RADIUS TO USE. |
| | THE WALL BY THE SPACE BLOCKS THE ABILITY |
| | OF SPACES 1-233 AND 1-234 TO SAFELY BACK |
| | OUT. |
| | |
| | 8) THE STOP BARS AT THE ANGLED SPACES BY |
| | THE ENTRANCE ARE INCORRECTLY PLACED. |
| | |
| | 9) 13 DISABLED SPACES, NOT 9 ARE |
| | REQUIRED FOR THE PROJECT. |
| | |
| | 10) LOCATION OF STOP BARS INCORRECT FOR |
| | COMPACT SPACES. |
| | |
| | 11) SPACE 1-196 TOO NARROW.SPACE 1-236 |
| | MARKED INCORRECTLY.SPACE 1-035 IS NOT |
| | DEEP ENOUGH. |
| | |
| | 12) WALLS ENCROACH INTO SPACES 1-047, |
| | 1-048, 1-065, 1-066, 1-068, 1-069, |
| | 1-086, 1-087, 1-104, 1-105, 1-122, |
| | 1-123, 1-125, 1-126, 1-143, 1-144, |
| | 1-166, 1-167, 1-178, 1-179, 1-184, |
| | 1-185, 1-204 AND 1-205. |
| | |
| | 13) ADJUST THE CURBING BY THE PARALLEL |
| | SPACES BY THE WEST ENTRANCE ISLAND TO |
| | HAVE 45 DEGREE ANGLES FOR EASIER |
| | PARKING. |
| | |
| | 14) SPACES 2-001, 2-002, 2-053, 2-092, |
| | 2-131, 2-172, 2-206 AND 2-207 HAVE |
| | COLUMNS INTRUDING IN THEM. |
| | |
| | 15) THE DISABLED ACCESS WAY BY SPACE |
| | 2HC-004 HAS COLUMNS INTRUDING IN IT. |
| | |
| | 16) SPACE 2-037 IS NOT DEEP ENOUGH. |
| | SPACES 2-198 AND 2-199 ARE NOT STRIPED |
| | CORRECTLY. |
| | |
| | 17) THE SPACE LABELED AS 2-202 MAY NOT |
| | BE COUNTED AS IT DOES NOT CONFORM TO ANY |
| | OF THE CODE REQUIREMENTS. |
| | |
| | 18) THE WALL ADJACENT TO SPACE 2-202 |
| | SPACE BLOCKS THE ABILITY OF SPACES 2-202 |
| | AND 2-203 TO SAFELY BACK OUT.THE WALL |
| | ALSO EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 19) THE COLUMN ADJACENT TO SPACE 2-036 |
| | EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 20) THE COLUMN BETWEEN SPACES 2-198 AND |
| | 2-199 EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 21) WALLS ENCROACH INTO SPACES 2-049, |
| | 2-050, 2-070, 2-071, 2-088, 2-089, |
| | 2-127, 2-128, 2-168, 2-169, 2-180, AND |
| | 2-181. |
| | |
| | 22) SPACES 3-001, 3-002, 3-053, 3-122, |
| | 3-161 AND 3-162 HAVE COLUMNS INTRUDING |
| | IN THEM. |
| | |
| | 23) SPACE 3-037 IS NOT DEEP ENOUGH. |
| | SPACES 3-148 AND 3-149 ARE NOT STRIPED |
| | CORRECTLY. |
| | |
| | 24) THE WALL ADJACENT TO SPACE 3-152 |
| | SPACE BLOCKS THE ABILITY OF SPACES 3-152 |
| | AND 3-153 TO SAFELY BACK OUT.THE WALL |
| | ALSO EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 25) THE COLUMN ADJACENT TO SPACE 3-036 |
| | EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 26) THE COLUMN BETWEEN SPACES 3-148 AND |
| | 3-149 EXTENDS INTO THE DRIVE AISLE. |
| | |
| | 27) WALLS ENCROACH INTO SPACES 3-049, |
| | 3-050, 3-067, 3-068, 3-070, 3-071, |
| | 3-088, 3-089, 3-108, 3-109, 3-118, |
| | 3-119, 3-130, 3-131, 3-136 AND 3-137. |
| | |
| | 28) IT APPEARS THAT THE RETAINING WALL |
| | ATTACHED TO THE BUILDING IS OUTSIDE OF |
| | THE PROPERTY LINE ON THE NORTH SIDE OF |
| | THE SITE AND MAY BE AN ISSUE IN THE |
| | SOUTHEAST CORNER.ALL RETAINING WALLS, |
| | PLANTER BOXES AND OTHER FEATURES |
| | ATTACHED TO THE BUILDING SHALL BE INSIDE |
| | THE PROPERTY LINE NOT IN THE PUBLIC |
| | RIGHT-OF-WAY.ENSURE THAT THIS |
| | REQUIREMENT IS MET AROUND THE ENTIRE |
| | BUILDING.SHOW THE PROPERTY LINES ON |
| | THE ELEVATIONS TO VERIFY THERE IS NO |
| | ENCROACHMENT. |
| | |
| | 29) A LANDSCAPE PLAN AND A SURVEY |
| | SHOWING THE BUILDING FOOTPRINT ARE |
| | REQUIRED. |
| | |
| | CONTACT ERIC SCHNEIDER @ 822-1435. |