2005-11-09 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
  
 COMMENTS FROM PREVIOUS REVIEW, NUMBERING
 TO REMAIN THE SAME FOR CONSISTENCY:
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY (CHANGE OF USE).THE PLANS
 MUST BE STAMPED AND THE RECEIPT ATTACHED
 TO THE APPLICATION. 233-5025
  
 7.)THE PLANS ARE TO BE SIGNED, SEALED,
 AND DATED ORIGINALS, FAC61G1-16.003.
  
 27.)THE HANDRAIL EXTENSIONS FOR BOTH
 STAIRS ARE TO COMPLY WITH FBC11-4.9.4.
 PLEASE PROVIDE A DETAIL SHOWING ALL
 DIMENSIONS.
  
 HANDRAILS NOT SHOWN FOR INTERIOR STAIR,
 FBC1007.5.5, FBC11-4.9.4.
  
 NOTE - NO PRODUCT APPROVALS SUBMITTED.
 FROM PREVIOUS REVIEW:
  
 34.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED IN ADDITION TO THE
 NOAS PROVIDED, FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 35.)PROVIDE LEGIBLE NOAS. THEY MAY BE
 AVAILABLE AT WWW.FLORIDABUILDNG.ORG OR
 WWW.MIAMIDADE.GOV (FIND A DEPARTMENT,
 BUILDING CODE COMPLIANCE, PRODUCT
 CONTROL SEARCH).
  
 36.)NON IMPACT GLAZED DOOR PRODUCT
 APPROVALS WERE SUBMITTED.PLEASE SEE
 ATTACHED POLICY IN REGARDS TO MISSILE
 IMPACT PROTECTION, ITEM #13.
  
 37.)FOR THE GAF BUILT UP ROOF,
 INDICATE WHICH APPROVED ASSEMBLY YOU ARE
 USING.
  
 38.)FOR THE METAL ROOF PANELS, PROVIDE
 DESIGN PRESSURES AND SEE PRODUCT
 LIMITATION #7.
  
 39.)ANY PRODUCT APPROVALS NOT REVIEWED
 PRIOR TO PERMIT ISSUANCE WILL REQUIRE
 SEPARATE PERMITS.
  
 NEW COMMENTS:
  
 40.)STATE OCCUPANT LOAD FOR THE SECOND
 FLOOR TO DETERMINE VERTICAL
 ACCESSIBILITY REQUIREMENTS,
 FBC11-4.1.3(5).