| Date |
Text |
| 2005-08-06 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05070748 |
| | ADD: 940 PASEO PALMERA |
| | CONT: O/B IVANKO, STIPO |
| | TEL: (561)659-2844 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) 2002.1 GENERAL. THE QUALITY, DESIGN, |
| | FABRICATION AND ERECTION OF ALUMINUM |
| | USED STRUCTURALLY IN BUILDINGS OR |
| | STRUCTURES SHALL CONFORM TO GOOD |
| | ENGINEERING PRACTICE. |
| | |
| | 2) FL. BLD CODE 1606.1.7 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 3) PROVIDE ENINEERING CHARTS SHOWING THE |
| | COLUMN SIZE & HEIGHT ON TABLE,CARRY BEAM |
| | & CLEAR SPAN TABLE, EITHER A CONTINOUS |
| | FOOTER OR ISOLATED PAD. |
| | |
| | 4)2002.2 STRUCTURAL ALUMINUM |
| | CONSTRUCTION. THE DESIGN, FABRICATION |
| | AND ASSEMBLY OF STRUCTURAL ALUMINUM FOR |
| | BUILDINGS OR STRUCTURES SHALL CONFORM |
| | TO SPECIFICATIONS FOR ALUMINUM |
| | STRUCTURES, ALUMINUM DESIGN MANUAL, PART |
| | 1, OF THE ALUMINUM ASSOCIATION.THE USE |
| | OF ALUMINUM ALLOYS NOT LISTED IN THE |
| | MANUAL SHALL BE PERMITTED PROVIDED THEIR |
| | STANDARD OF PERFORMANCE IS NOT LESS THAN |
| | THOSE REQUIRED IN THE MANUAL AND THE |
| | PERFORMANCE IS SUBSTANTIATED TO THE |
| | SATISFACTION OF THE BUILDING OFFICIAL. |
| | |
| | 5)2002.3.1 ACTUAL WALL THICKNESS OF |
| | EXTRUDED ALUMINUM MEMBERS SHALL BE |
| | NOT LESS THAN 0.040 INCH (1 MM). |
| | |
| | 6)2002.3.2 SCREEN DENSITY SHALL BE A |
| | MAXIMUM OF 20 X 20 MESH. |
| | |
| | 7)2002.3.3 VINYL AND ACRYLIC PANELS |
| | SHALL BE REMOVABLE.REMOVABLE PANELS |
| | SHALL BE IDENTIFIED AS REMOVABLE BY A |
| | DECAL.THE IDENTIFICATION DECAL |
| | SHALL ESSENTIALLY STATE "REMOVABLE PANEL |
| | SHALL BE REMOVED WHEN WIND SPEEDS EXCEED |
| | 75 MPH (34 M/S)".DECALS SHALL BE |
| | PLACED SUCH THAT THE DECAL IS VISIBLE |
| | WHEN THE PANEL IS INSTALLED. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |
| | |
| | |
| | |