| Date |
Text |
| 2005-08-15 00:00:00 | DENIED |
| | |
| | 1)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 3) THE TRUSS LAYOUT HAS THE SIGNATURE |
| | AND SEAL OF TWO DIFFERENT ENGINEERS. |
| | ONLY THE ENGINEER IN RESPONSIBLE CHARGE |
| | OF THE PREPARATION AND PRODUCTION OF THE |
| | DOCUMENT SHOULD SIGN AND SEAL IT. SEE |
| | FAC 61G-15-23.002. |
| | |
| | 4) THE DESIGNER OF RECORD FOR THE |
| | STRUCTURE SHOULD PROVIDE A ROOF FRAMING |
| | PLAN. FBC 104.2 |
| | |
| | 5) SHEET A-1 SPECIFIES HEADER |
| | CONNECTIONS AS (2) HETA 20 CONNECTORS. |
| | PLEASE CLARIFY. DOES THIS REFER TO THE |
| | CONNECTORS FOR THE WOOD BEAMS AT THE |
| | FRONT PORCH? IF SO, THEY SHOULD BE WOOD |
| | TO WOOD CONECTORS. SPECIFY CONNECTORS |
| | FOR THIS LOCATION. |
| | |
| | 6) THE TRUSS DRAWINGS AND LAYOUT ARE NOT |
| | REQUIRED TO BE SUBMITTED FOR PLAN |
| | REVIEW. SIGNED AND SEALED DRAWINGS AND |
| | LAYOUT ARE REQUIRED TO BE GIVEN TO THE |
| | FIELD INSPECTOR AT TIME OF INSPECTION. |
| | |
| | 7) SPECIFY THE SIZE AND LOCATION OF THE |
| | ATTIC ACCESS AS REQUIRED BY FBC 2309.6. |
| | |
| | |
| | 8) ON SHEET A-1 THE FOOTING SIZE IS |
| | SPECIFIED AS 18" X 14". THIS CONFLICTS |
| | WITH THE SIZE SPECIFIED ON SHEET A-2. |
| | THE FOOTING IS REQUIRED BY FBC 1804.1.3 |
| | TO EXTEND A MINIMUM OF 12" BELOW GRADE |
| | AND CITY AMENDMENTS TO FBC 1804.1.7 |
| | REQUIRE THE FLOOR ELEVATION TO BE A |
| | MINIMUM OF 4 INCHES ABOVE GRADE AT |
| | HABITABLE AREAS. |
| | |
| | 9) THE DESIGN PRESSURE TABLE ON A-1 HAS |
| | NOTES THAT REFERENCE THE PBC. THE |
| | CORRECT REFERENCE IS 2001 FBC. |
| | |
| | 10) PLEASE LABEL THE COMPONENT AND |
| | CLADDING TABLE ON A-1 FOR ZONES 4 AND 5. |
| | SEE FBC TABLE 1606.2B. |
| | |
| | 11) THE WINDOW BUCK DETAIL ON A-2 DOES |
| | NOT COMPLY WITH FBC 1707.4.4.2 WHICH |
| | REQUIRES WINDOW AND DOOR FRAMES TO BE |
| | FASTENED THROUGH 1X BUCKS INTO THE |
| | STRUCTURAL SUBSTRATE. THIS DETAIL ALSO |
| | CONFLICTS WITH THE ONE ON SHEET A-1. |
| | |
| | 12) SPECIFY ON SHEET A-1 THAT THE |
| | INTERNAL PRESSURE IS POSITIVE AND |
| | NEGATIVE 0.18. SEE ASCE 7-98. |
| | |
| | 13) THE CORRECT COMPONENT AND CLADDING |
| | TABLE IS 1606.2B. PLEASE CORRECT THIS |
| | UNDER WIND INFORMATION ON A-1. |
| | |
| | 14) PLEASE REMOVE THE COPIES OF THE BUCK |
| | DETAILS ATTACHED TO THE PRODUCT |
| | APPROVALS. BUCK DETAILS ARE REQUIRED ON |
| | THE PLANS. |
| | |
| | 15) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. THIS IS |
| | REQUIRED IN ADDITION TO THE NOA OR OTHER |
| | EVAUALATION DOCUMENTS. |
| | |
| | 16) SUBMIT PRODUCT APPROVAL FOR STATE OR |
| | LOCAL WITH INSTALLATION INSTRUCTIONS FOR |
| | THE SLIDING GLASS DOORS. |
| | |
| | 17) THE INSTALLATION DRAWINGS WITH THE |
| | KD WINDOWS NOA DO NOT HAVE THE MIAMI |
| | DADE NOA STAMP AND SIGNATURE ON THEM. |
| | THEY ARE NOT VALID WITHOUT THE STAMP AND |
| | SIGNATURE. |
| | |
| | 18) SUBMIT TWO COPIES OF A KEY PLAN AND |
| | INSTALLATION SCHEDULE FOR THE STORM |
| | PANLES. LIST THE ANCHOR TYPE AND |
| | SPACING. SPECIFY THE MOUNT TYPE THAT |
| | WILL BE INSTALLED. A SEPARATE PERMIT |
| | WILL BE REQUIRED IF THIS INFORMATION IS |
| | NOT PROVIDED AT TIME OF PERMIT. |
| | |
| | 19) THE INFORMATION ON THE ENERGY |
| | CALULATION FORMS DOES NOT MATCH THE |
| | PLANS. SEVERAL OTHER ITEMS ARE INCORRECT |
| | ON THE FORM. |
| | |
| | 20) THE CALCULATED VALUE OF THE |
| | STRUCTURE HAS BEEN INCREASE BASED ON ICC |
| | CONSTRUCTION VALUE TABLES. |
| | |
| | PLEASE SUBMIT ONE COPY OF OLD PLAN |
| | SHEETS IF NEW SHEETS ARE SUBMITTED AS |
| | THIS WILL HELP TO FACILITATE THE PLAN |
| | REVIEW PROCESS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |
| | |
| | |