Plan Review Notes
Plan Review Notes For Permit 05070627
Permit Number 05070627
Review Stop P
Sequence Number 5
Notes
Date Text
2006-04-22 00:00:00PASSED/PROVISO
  
 REVISION REQUIRED FOR SHT P1.1B SHOWING
 VENT FOR LIFT STATION & ROUTING OF STEAM
 LINE TO PITCH AWAY FROM THE STEAM
 GENERATOR TO DRAIN THE CONDENSATE. SEE
 SHT 8 0F 19 MANUF. SPECIFICATION SHEETS.
 (I WAS INFORMED BY THE DESIGN
 PROFESSIONAL THAT THE STEAM GENERATOR
 WILL BE MOVED)
  
 REVISION REQUIRED FOR SHT SHT P5.1 FOR
 ALL RED LINE CHANGES TO GAS ISOMETRIC &
 PLUMBING RISERS.
  
 REVISION REQUIRED FOR SHEET P5.2
 INDICATING THAT A STANDPIPE IS REQUIRED
 FOR THE DISH WASHER PER SECTION 802.17.
  
 ALL REVISIONS SHALL BE SUBMITTED AS SOON
 AS POSSIBLE TO AVOID A DELAY IN GETTING
 THE CERTIFICATE OF OCCUPANCY.