Plan Review Notes
Plan Review Notes For Permit 05070499
Permit Number 05070499
Review Stop P
Sequence Number 2
Notes
Date Text
2005-11-18 00:00:00PAUL SCHMITZ
 FBC2001 FUEL GAS CODEPLAN REVIEW
 FBC 2001 PLUMBING CODEPLAN REVIEW
 FBC 2001 FL ACESSIBILITY CODE PLAN
 REVIEW
 DENIED
 1( CHANGE OF OCCUPANCY FROM BUSINESS TO
 ASSEMBLY.
 SECTION P403 MINIMUM PLUMBING FACILITIES
  
 ?P403.1 MINIMUM NUMBER OF FIXTURES.
 PLUMBING FIXTURES SHALL BE PROVIDED
 FOR THE TYPE OF OCCUPANCY AND IN THE
 MINIMUM NUMBER SHOWN IN TABLE P403.1.
 TYPES OF OCCUPANCIES NOT SHOWN IN TABLE
 P403.1 SHALL BE CONSIDERED
 INDIVIDUALLY BY THE CODE OFFICIAL.THE
 NUMBER OF OCCUPANTS SHALL BE
 DETERMINED BY THE BUILDING CODE.
 OCCUPANCY CLASSIFICATION SHALL BE
 DETERMINED IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE, BUILDING.
 PROVIDE SHOW DETAIL
 2)1-4.22 TOILET ROOMS.SHOW DETAIL
 ?11-4.22.1 MINIMUM NUMBER. TOILET
 FACILITIES REQUIRED TO BE ACCESSIBLE
 BY ?11-4.1 SHALL COMPLY WITH ?11-4.22.
 ACCESSIBLE TOILET ROOMS SHALL BE
 ON AN ACCESSIBLE ROUTE.
 ?11-4.22.2 DOORS.
 ?11-4.22.2(1) ALL DOORS TO ACCESSIBLE
 TOILET ROOMS SHALL COMPLY WITH
 ?11-4.13.DOORS SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE REQUIRED FOR ANY
 FIXTURE.
 ?11-4.22.3 CLEAR FLOOR SPACE. THE
 ACCESSIBLE FIXTURES AND CONTROLS
 REQUIRED IN ?11-4.22.4, ?11-4.22.5,
 ?11-4.22.6, AND ?11-4.22.7 SHALL BE
 ON AN ACCESSIBLE ROUTE.AN
 UNOBSTRUCTED TURNING SPACE COMPLYING
 WITH 11-
 4.2.3 SHALL BE PROVIDED WITHIN AN
 ACCESSIBLE TOILET ROOM.THE CLEAR FLOOR
 SPACE AT FIXTURES AND CONTROLS, THE
 ACCESSIBLE ROUTE, AND THE TURNING
 SPACE MAY OVERLAP.
 ?11-4.22.4 WATER CLOSETS. IF TOILET
 STALLS ARE PROVIDED, THEN AT LEAST
 ONE SHALL BE A STANDARD TOILET STALL
 COMPLYING WITH ?11-4.17; WHERE 6 OR
 MORE STALLS ARE PROVIDED, IN ADDITION
 TO THE STALL COMPLYING WITH
 ?11-4.17.3, AT LEAST ONE STALL 36 IN
 (915 MM) WIDE WITH AN OUTWARD
 SWINGING, SELF-CLOSING DOOR AND
 PARALLEL GRAB BARS COMPLYING WITH
 FIGURE 11-30(D) AND ?11-4.26 SHALL BE
 PROVIDED.WATER CLOSETS IN
 SUCH STALLS SHALL COMPLY WITH
 ?11-4.16.IF WATER CLOSETS ARE NOT IN
 STALLS, THEN AT LEAST ONE SHALL COMPLY
 WITH ?11-4.16.
 ?11-4.22.5 URINALS. IF URINALS ARE
 PROVIDED, THEN AT LEAST ONE SHALL
 COMPLY WITH ?11-4.18.
 ?11-4.22.6 LAVATORIES AND MIRRORS. IF
 LAVATORIES AND MIRRORS ARE
 PROVIDED, THEN AT LEAST ONE OF EACH
 SHALL COMPLY WITH ?11-4.19.
 ?11-4.22.7 CONTROLS AND DISPENSERS. IF
 CONTROLS, DISPENSERS,
 RECEPTACLES, OR OTHER EQUIPMENT ARE
 PROVIDED, THEN AT LEAST ONE OF EACH
 SHALL BE ON AN ACCESSIBLE ROUTE AND
 SHALL COMPLY WITH ?11-4.27.
 END OF COMENTS QUESTIONS 561-805-6692