| 2005-11-10 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | COMMENTS FROM PREVIOUS REVIEW, NUMBERING |
| | REMAINING THE SAME FOR CONSISTENCY |
| | |
| | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | FS713.13 REQUIRES THE CONTRACTOR?S NAME |
| | AND ADDRESS SO THAT NOTICES CAN BE |
| | SERVED AS REQUIRED BY THE FLORIDA LEIN |
| | LAW.CONTRACTOR ADDRESS IS NOT ON THE |
| | NOC. |
| | |
| | 5.)THIS PARCEL IS IN A FLOOD ZONE.A |
| | FORM BOARD ELEVATION CERTIFICATE WILL BE |
| | REQUIRED.THE FINISHED FLOOR IS TO BE |
| | SIX INCHES ABOVE BASE FLOOD ELEVATION, |
| | CITY OF WEST PALM BEACH MUNICIPAL CODE |
| | 94-546(2). NOTE MINIMUM ELEVATION ON THE |
| | PLAN. |
| | |
| | NOT ADDRESSED. |
| | |
| | 6.)SIGN THE OWNER/AGENT LINE OF THE |
| | ENERGY CALCS. |
| | |
| | 7.)A WAREHOUSE SHOULD BE S OCCUPANCY, |
| | THE OFFICE AREA IS B.PLEASE SEE FBC312 |
| | AND FBC305.BUSINESS OCCUPANCY WAS |
| | DECLARED ON SHEET A2. |
| | |
| | NOT ADDRESSED; STILL SHOWS A WAREHOUSE |
| | AND DECLARES B OCCUPANCY.BASED ON THE |
| | FLOOR PLAN WHICH SHOWS A WAREHOUSE, THE |
| | OFFICES ARE ACCESSORY TO THE PRIMARY |
| | OCCUPANCY OF STORAGE, SEE FBC704.1.2.1. |
| | |
| | |
| | 8.)PROVIDE A SITE PLAN, FBC*104.3.1.1. |
| | SHOW ALL DISTANCES FROM THE PROPERTY |
| | LINE SO THAT TABLE 500 AND TABLE 600 |
| | COMPLIANCE CAN BE DETERMINED.SHOW |
| | ACCESSIBLE PARKING, ACCESSIBLE ROUTE |
| | FROM THE PUBLIC WAY FBC CHAPTER 11. |
| | |
| | 9.)THE AREA INCREASE CALCULATIONS ON |
| | A2 STATES THAT THE ALLOWABLE AREA FOR |
| | BUSINESS TYPE V IS 9000 SF.PLEASE NOTE |
| | THAT IT IS 14000 SF PER FBC TABLE 500 |
| | AND 16000 FOR STORAGE. |
| | |
| | YOU HAVE CHANGED THE BUILDING TYPE TO |
| | VI.AREA ALLOWED FOR TYPE VI, STORAGE |
| | OCCUPANCY, UNPROTECTED UNSPRINKLED IS |
| | 6000.THE BUILDING IS NOT COMPLIANT FBC |
| | TABLE 500. |
| | |
| | 12.)CLARIFY THE ROOF AREA ON A3. |
| | |
| | 13.)DOOR HARDWARE TO COMPLY WITH |
| | FBC11-4.13.9. |
| | |
| | THIS WAS ADDRESSED BY PROVIDING THE CODE |
| | SECTION.PLANS ARE TO BE PROVIDE DESIGN |
| | CRITERIA, FBC*104.2.1. |
| | |
| | 16.)THE FOLLOWING NOAS WERE REVIEWED |
| | AND APPEAR CODE COMPLIANT EXCEPT AS |
| | NOTED BUT REQUIRE FLORIDA STATE OR LOCAL |
| | PRODUCT APPROVALS, FAC9B72. |
| | WWW.FLORIDABUILDING.ORG. |
| | |
| | ARCH ALUMINUM IMPACT WALL 3000 |
| | ARCH ALUMINUM MAGNUM STILE ENTRANCE DOOR |
| | MODEL 651 ROLLING DOOR ? EXPIRED NOA |
| | |
| | FLORIDA PRODUCT APPROVALS REQUIRED IN |
| | ADDITION TO THE NOAS PROVIDED, FAC9B72. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 17.)PROVIDE PRODUCT APPROVALS FOR THE |
| | REAR METAL DOOR, FLAT ROOF, STANDING |
| | SEAM, ROLLING DOOR.ANY PRODUCT |
| | APPROVALS NOT REVIEWED PRIOR TO PERMIT |
| | ISSUANCE WILL REQUIRE SEPARATE PERMITS. |
| | |
| | FLORIDA PRODUCT APPROVALS REQUIRED |
| | FAC9B72, WWW.FLORIDABUILDNIG.ORG |
| | |
| | 18.)SEE ATTACHED FS553.80(2)(B).A 4X |
| | PLAN REVIEW FEE WILL BE CHARGED IF |
| | COMMENTS ARE NOT ADDRESSED IN THE NEXT |
| | REVIEW. |
| | |