| Date |
Text |
| 2006-01-21 00:00:00 | PAUL SCHMITZ |
| | FBC 2001 PLUMBING CODE PLAN REVIEW |
| | FBC 2001 CH 11, FL ACESSIBILITY CODE |
| | DENIED 3RD TIME |
| | |
| | 1)SHT A-1 DEMOLITION PLAN NOTES. |
| | ?P704.5 DEAD ENDS. IN THE INSTALLATION |
| | OR REMOVAL OF ANY PART OF A |
| | DRAINAGE SYSTEM, DEAD ENDS SHALL BE |
| | PROHIBITED. |
| | 2. SHT A-1A SHOWS A KITCHEN SINK. |
| | THE SINK SHALL BE ACCESSIBLE. |
| | PLEASE SUBMIT A DETAIL, SHOWING |
| | COMPLIANCE WITH SECTION 11-4.24 AND ALL |
| | SUBSECTIONS, TO THIS COMMENT. |
| | FORWARD APPROACH REQUIRED WITH NO |
| | CABINET DOORS ALLOWDED. |
| | ?11-4.24.1 GENERAL. SINKS REQUIRED TO |
| | BE ACCESSIBLE BY ?11-4.1 SHALL |
| | COMPLY WITH ?11-4.24. |
| | ?11-4.24.2 HEIGHT. SINKS SHALL BE |
| | MOUNTED WITH THE COUNTER OR RIM NO |
| | HIGHER THAN 34 IN. (865 MM) ABOVE THE |
| | FINISH FLOOR. |
| | ?11-4.24.3 KNEE CLEARANCE. KNEE |
| | CLEARANCE THAT IS AT LEAST 27 IN. (685 |
| | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 |
| | IN (485 MM) DEEP SHALL BEPROVIDED |
| | UNDERNEATH SINKS. |
| | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A |
| | MAXIMUM OF 6-1/2 IN (165 MM)DEEP. |
| | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR |
| | FLOOR SPACE AT LEAST 30 IN. BY 48 |
| | IN. (760 MM BY 1220 MM) COMPLYING WITH |
| | 11-4.2.4 SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD |
| | APPROACH.THE CLEAR FLOOR SPACE SHALL |
| | BE ON AN ACCESSIBLE ROUTE AND SHALL |
| | EXTEND A MAXIMUM OF 19 IN. (485 MM) |
| | UNDERNEATH THE SINK (SEE FIGURE |
| | 11-32). |
| | ?11-4.24.6 EXPOSED PIPES AND SURFACES. |
| | HOT WATER AND DRAIN PIPES EXPOSED |
| | UNDER SINKS SHALL BE INSULATED OR |
| | OTHERWISE CONFIGURED SO AS TO PROTECT |
| | AGAINST CONTACT.THERE SHALL BE NO |
| | SHARP OR ABRASIVE SURFACES UNDER |
| | SINKS.( NO GARBAGE DISPOSAL) |
| | ?11-4.24.7 FAUCETS. FAUCETS SHALL |
| | COMPLY WITH ?11-4.27.4.LEVER- |
| | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR |
| | ELECTRONICALLY CONTROLLED MECHANISMS |
| | ARE ACCEPTABLE DESIGNS. |
| | 11-4.22.2 DOORS SHALL NOT SWING INTO THE |
| | CLEAR FLOOR SPACE REQUIRED FOR A FIXTURE |
| | 3. SUBMIT A SANT. AND A WATER RISER |
| | DIAGRAM IN ISOMETRIC FORM. SHOW ALL PIPE |
| | SIZES, TRAP, VENT/SANT CONNECTIONS FOR |
| | THE SANT. AND SHOW ALL PIPE SIZES, |
| | VALVES, WATER HAMMER ARRESTORS, (IF |
| | REQUIRED BY SECTION 604.9), AND POINT OF |
| | CONNECTION. SECTION 104.3.1.1. - NO |
| | RESPONSE TO COMMENT. |
| | |
| | END OF COMMENTS, QUESTIONS 561-805-6692 |