2005-11-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
  
 1. BOTH SETS OF MECHINCAL AND ELECTRICAL
 SHEETS SHALL BE SIGNED, SEALED, AND
 DATED PER FAC 61G15-23.002(1) & FS
 471.2055. - STILL SHEET NOT SIGNED,
 SEALED, DATED
 2. SHT A-1 SHOWS A KITCHEN SINK, AND
 SINCE THERE IS NO DEMO SHEET, EXISTING
 FLOOR PLAN, OR NOT INDICATED AS AN
 EXISTING SINK, THE SINK SHALL BE
 ACCESSIBLE. PLEASE SUBMIT A DETAIL
 SHOWING COMPLIANCE WITH SECTION 11-4.24
 AND ALL SUBSECTIONS. - NO RESPONSE NOTED
 TO THIS COMMENT. - FORWARD APPROACH
 REQUIRED WITH NO CABINET DOORS ALLOWDED.
 ALSO DOOR CAN NOT SWING INTO CLEAR FLOOR
 SPACE OF ANY FIXTURE.
 3. SUBMIT A SANT. AND A WATER RISER
 DIAGRAM IN ISOMETRIC FORM. SHOW ALL PIPE
 SIZES, TRAP, VENT/SANT CONNECTIONS FOR
 THE SANT. AND SHOW ALL PIPE SIZES,
 VALVES, WATER HAMMER ARRESTORS, (IF
 REQUIRED BY SECTION 604.9), AND POINT OF
 CONNECTION. SECTION 104.3.1.1. - NO
 RESPONSE TO COMMENT.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]