Plan Review Notes
Plan Review Notes For Permit 05070206
Permit Number 05070206
Review Stop B
Sequence Number 1
Notes
Date Text
2005-07-22 00:00:00DENIED
  
 1) THE WRONG PRESSURES ARE CIRCLED ON
 THE COMPONENT AND CLADDING SHEETS. THE
 FIRST TABLE SHOULD BE USED. THE
 EFFECTIVE WIND AREA SHALL NOT BE GREATER
 THAN THE AREA THAT IS TRIBUTARY TO AN
 INDIVIDUAL FASTENER. SEE ASCE 7-98.
  
 2) PRODUCT APPROVALS SUBMITTED
 WITH PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT WWW.FLORIDABUILDING.ORG. PRODUCTS
 WITH STATEWIDE APPROVAL ARE REQUIRED TO
 BE SUBMITTED WITH A COVER SHEET THAT
 LISTS THE PRODUCT IDENTITY NUMBER (FL#)
 FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICA- TION FOR LOCAL PRODUCT APPROVAL
 OR SITE SPECIFIC FORM PER RULE 9B-72.
  
 3) THERE IS A PRODUCT CODE GT THAT IS
 NOT LISTED IN THE SHUTTER PRODUCT KEY.
  
 4) MULTIPLE FASTENERS, SPACINGS AND
 SEPARATIONS FROM GLASS ARE CIRCLED ON
 THE DRAWINGS. SUBMIT AN INSTALLATION
 SCHEDULE WITH THE REQUIRED INFORMATION
 AND IN THE FORM OF THE SAMPLE THAT IS
 ATTACHED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  