| Date |
Text |
| 2005-08-08 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 1 |
| | FBC-2001 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. SHT 3.1 MEZZANINE FLOOR PLAN. PRIVATE |
| | BATHROOM SHALL BE ADAPTABLE. INDICATE |
| | BACKING FOR ALL GRAB BARS FOR TOILET & |
| | SHOWER, 5' TURNING AREA. WATER CLOSET |
| | SHALL BE 18" FROM WALL TO CENTERLINE OF |
| | FIXTURE. (SEE SECTION 11-4.16.4). |
| | SECTION 11-4.1.3(11). |
| | 2. SINKS ON FIRST FOOR AND ON MEZZANINE |
| | LEVEL SHALL BE ACCESSIBLE. PLEASE SUBMIT |
| | A DETAIL FOR SINKS COMPLYING WITH THE |
| | FOLLOWING: |
| | A. 11-4.24.2 HEIGHT |
| | B. 11-4.24.3 KNEE CLEARANCE |
| | C. 11-4.24.4 SINK DEPTH |
| | D. 11-4.24.5 CLEAR FLOOR SPACE. - |
| | FORWARD APPROACH REQUIRED AND SHALL |
| | EXTEND A MAXIMUM OF 19" UNDERNEATH THE |
| | SINK. |
| | E. 11-4.24.6 EXPOSED PIPES & SURFACES |
| | F. 11-4.24.7 FAUCETS. |
| | 3. SHT 10.1 DRINKING FOUNTAIN DETAIL, |
| | SHOW COMPLIANCE WITH 11-15.4.1.3(10)(A) |
| | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY |
| | BENDING OR STOOPING. |
| | 4. SHTS ME.1 & ME.2 IF THE DESIGN |
| | PROFESSIONAL IS AN ENGINEER THEN HE/SHE |
| | SHALL AFFIX HIS/HER OFFICIAL SEAL TO |
| | SAID DRAWINGS AS REQUIRED BY FLORIDA |
| | STATUTES. SECTION 104.2.2. |
| | 5. SHT ME.1 SANITARY RISER DIAGRAM DOES |
| | NOT REFLECT THE FLOOR PLAN, NOR DOES IT |
| | MEET CODE REQUIREMENTS. CORRECT THE |
| | FOLLOWING: |
| | A. THE SNACK SINK SHALL NOT CONNECT TO |
| | THE WET VENT FOR THE BATHROOM FIXTURES. |
| | THE SINK SHALL DISCHARGE DOWNSTREAM OF |
| | THE BATHROOM FIXTURES. SECTION 909.1. |
| | B. THE BATHROOM FIXTURES OF THE |
| | MEZZANINE SHALL NOT DRAIN PAST THE VENT |
| | FOR THE 1ST FLOOR FIXTURES. SECTION |
| | 908.3. |
| | C. THE MEZZANINE LEVEL SINK IN THE OPEN |
| | OFFICE (521) IS NOT SHOWN ON THE SANT. |
| | RISER DIAGRAM. SECTION 104.2.1. |
| | D. MEZZANINE PIPING DOES NOT REFLECT |
| | THE FLOOR PLAN. RISER SHOWS THE LAV AND |
| | SHOWER ON THE SAME SIDE OF THE ROOM. |
| | SECTION 104.2.1. |
| | 6. SUBMIT A WATER RISER DIAGRAM IN |
| | ISOMETRIC FORM. SECTION 104.3.1.1. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |