| 2005-07-31 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05070083 |
| | ADD: 6118 WILDCAT RUN |
| | CONT:O/B FAKHARI, MOHAMMAD |
| | TEL: (561)310-7460 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | THE PERMIT APPLICATION DOESN'T INDICATE |
| | WHAT MATERIALS THE EXISTING FIREPLACE |
| | NOR CHIMNEY IS MADE OF. IF THE FIREPLACE |
| | AND OR CHIMNEY IS FACTORY BUILT, IT HAS |
| | TO CONFORM TO THOUGHS SPECIFICATIONS |
| | UNDER WHICH IT WAS BUILT AND TESTED. |
| | |
| | 2806.1.1 FACTORY-BUILT FIREPLACES SHALL |
| | BE LISTED AND SHALL BE INSTALLED |
| | IN ACCORDANCE WITH THE CONDITIONS OF |
| | THE LISTING. |
| | |
| | 2806.1.2 FACTORY-BUILT FIREPLACES |
| | SHALL BE TESTED IN ACCORDANCE WITH |
| | AND MEET THE REQUIREMENTS OF UL 127. |
| | |
| | 2804.4.1 FACTORY-BUILT CHIMNEYS SHALL BE |
| | LISTED AND SHALL BE INSTALLED |
| | IN ACCORDANCE WITH THE CONDITIONS OF |
| | THE LISTING, AND THE MANUFACTURER'S |
| | INSTRUCTIONS.NOTHING CONTAINED IN |
| | THIS CODE SHALL BE CONSTRUED AS |
| | PROHIBITING THE USE OF INSULATED |
| | SUSPENDED FACTORY-BUILT CHIMNEYS |
| | PROVIDED SUCH ASSEMBLIES HAVE BEEN |
| | TESTED AND APPROVED BY A RECOGNIZED |
| | LABORATORY FOR THE USE INTENDED AND |
| | ARE INSTALLED IN ACCORDANCE WITH |
| | THEIR APPROVAL. |
| | |
| | |
| | ALTERING THE END CAPS AND THE DISPERSION |
| | OF SMOKE AND HEAT WITH THE DRAWINGS |
| | BY P.E. GORDON BUCK IS NOT RECOGNIZED |
| | NOR TESTED BY UL 127. |
| | BUILDING PLAN REVIEW |