2005-08-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05070071
 ADD: 833 BISCAYNE DR
 CONT: H. CANO
 TEL: (561)543-1290
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS
 B) EXTERIOR DOORS
 C) TRUSS/ WOOD TO WOOD ANCHORS
 D) ROOFING ASSEMBLIES
  
 3) PLANS INDICATE A PERMIT WAS PULLED TO
  
 REPLACE WINDOWS, NO PERMIT IS INDICATED
 FOR THIS ADDRESS, SEE ATTACHMENT.
  
 4) PLANS DO NOT INDICATE THE
 MANUFACTURING COMPANY FOR HOLDOWN
 ANCHORS. ALSO INDICATE LOADS TO BE
 IMPOSED UPLIFT, LATERAL & GRAVITY LOADS.
 PROVIDE THE MANUFATURES DESIGN PRESSURES
 TO BE USED.
 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 5)TRUSS ANCHORS:1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 6) PLANAS DO NOT INDICATE TERMITE
 TREATMENT OF SOILS:1 TERMITE PROTECTION.
 TERMITE PROTECTION SHALL BE PROVIDED BY
 REGISTERED TERMITICIDES, INCLUDING SOIL
 APPLIED PESTICIDES, BAITING SYSTEMS, AND
 PESTICIDES APPLIED TO WOOD, OR OTHER
 APPROVED METHODS OF TERMITE PROTECTION
 LABELED FOR USE AS A PREVENTATIVE
 TREATMENT TO NEW CONSTRUCTION.SEE 202,
 REGISTERED TERMITICIDE.UPON COMPLETION
 OF THE APPLICATION OF THE TERMITE
 PROTECTIVE TREATMENT, A CERTIFICATE OF
 COMPLIANCE SHALL BE ISSUED TO THE
 BUILDING DEPARTMENT BY THE LICENSED PEST
 CONTROL COMPANY THAT CONTAINS THE
 FOLLOWING STATEMENT:"THE BUILDING HAS
 RECEIVED A COMPLETE TREATMENT FOR THE
 PREVENTION OF SUBTERRANEAN TERMITES.
 TREATMENT IS IN ACCORDANCE WITH RULES
 AND LAWS ESTABLISHED BY THE FLORIDA
 DEPARTMENT OF AGRICULTURE AND CONSUMER
 SERVICES."
 1816.1.4 IF SOIL TREATMENT IS USED FOR
 SUBTERRANEAN TERMITE PREVENTION,
 CHEMICALLY TREATED SOIL SHALL BE
 PROTECTED WITH A MINIMUM 6 MIL VAPOR
 RETARDER TO PROTECT AGAINST RAINFALL
 DILUTION.IF RAINFALL OCCURS BEFORE
 VAPOR RETARDER PLACEMENT, RETREATMENT
 IS REQUIRED.ANY WORK, INCLUDING
 PLACEMENT OF REINFORCING STEEL, DONE
 AFTER CHEMICAL TREATMENT UNTIL THE
 CONCRETE FLOOR IS POURED, SHALL BE
 DONE IN SUCH MANNER AS TO AVOID
 PENETRATING OR DISTUBING TREATED
  
 7) PLANS INDICATE THE USE OF 1X3 PECKY
 CYPRESS UNDER THE ROOF, 5/8" CDX PLYWOOD
  
 WILL NEED TO BE OVER THE PECKY CYPRESS
 TO NAIL ROOFING MATERIALS TOO.
  
 8) PROVIIDE FOR ATTIC VENTING:
 2309.7.2 FOR FLAT ROOFS, BLOCKING AND
 BRIDGING SHALL BE ARRANGED SOAS NOT
 TO INTERFERE WITH THE MOVEMENT OF AIR.
 SUCH ROOFS SHALL BEVENTILATED ALONG
 THE OVERHANGING EAVES, WITH THE NET AREA
 OF OPENINGBEING NOT LESS THAN 1/250
 OF THE AREA OF THE CEILING BELOW.
  
 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 10) PLANS DO NOT INDICATE ELECTRICAL
 NOR PLUMBING WORK WHICH WILL REQUIRE
 REVIEW AND SEPERATE PERMITS.
  
 11) PLANS INDICATE REPAIR OF EXISTING
 DRIVEWAY AND SIDEWALK, PROVIDE WHAT
 REPAIR, APPLICATION INDICATES
 REPLACEMENT? PROVIDE MORE INFORMATION?
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026