| 2006-02-24 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05061880 |
| | ADD: 5400 S DIXIE HWY |
| | CONT: CONSILIUM ATLANTIC |
| | TEL: (954816-3351 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION |
| | ACTION: DENIED |
| | |
| | |
| | ****NOTE*** |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 1) ARCH THE MIAMI-DADE NOA SUBMITTED |
| | UNDER ARCH / STOREFRONTS DOES NOT HAVE |
| | FLORIDA APPROVAL/ LOCALPRODUCT APPROVAL |
| | WOULD BE REQUIRED. |
| | |
| | 2) ARCH SHOP DRAWINGS INDICATE THE |
| | DESIGN TO BE UNDER THE 2004 FBC, CORRECT |
| | TO 2001 FBC. |
| | |
| | 3) SHOP DRAWINGS INDICATE USE OF |
| | STRUCTURAL MULLIONS BUT NO APPROVAL: |
| | 1707.4.5.1 MULLIONS OCCURRING BETWEEN |
| | INDIVIDUAL WINDOW AND GLASS |
| | DOOR ASSEMBLIES. TESTING REPORTS ARE |
| | REQUIRED BY AN APPROVED TESTING |
| | LABORATORY OR BE ENGINEERED. |
| | |
| | 4)1707.4.5.2 MULLIONS SHALL BE DESIGN- |
| | ED TO TRANSFER THE DESIGN PRESSURE LOADS |
| | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES |
| | TO THE ROUGH OPENING SUBTRATE. |
| | |
| | 5) SHOP DRAWINGS INDICATE MULLIONS BY |
| | BESAM, THERE IS NO PRODUCT APPROVALS |
| | UNDER THIS NAME FOR MULLIONS. |
| | SEE RULE 9B72(29)(B) REQUIRING PRODUCT |
| | APPROVALS FOR MULLIONS. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |