2005-08-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05061880
 ADD: 5400 S DIXIE HWY
 CONT: CONSILIUM ATLANTIC
 TEL: (954)788-3884
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 THERE ARE PAGES MISSING THE RAISED SEAL,
 AND PAGES MISSING BOTH THE SEAL &
 SIGNATURE.
  
 4) ACCESSIBLE DRESSING ROOM ISMISSING
 BENCH:11-4.35.4 BENCH. EVERY ACCESSIBLE
 DRESSING ROOM SHALL HAVE A 24 IN. BY
 48 IN.(610 MM BY 1220 MM) BENCH FIXED
 TO THE WALL ALONG THE LONGER
 DIMENSION.THE BENCH SHALL BE MOUNTED
 17 IN. TO 19 IN.(430 MM TO 485 MM)
 ABOVE THE FINISH FLOOR.CLEAR FLOOR
 SPACE SHALL BE PROVIDED ALONGSIDE THE
 BENCH TO ALLOW A PERSON USING A
 WHEELCHAIR TO MAKE A PARALLEL TRANSFER
 ONTO THE BENCH.THE STRUCTURAL STRENGTH
 OF THE BENCH AND ATTACHMENTS SHALL
 COMPLY WITH ?11-4.26.3.WHERE INSTALLED
 IN CONJUNCTION WITH SHOWERS, SWIMMING
 POOLS, OR OTHER WET LOCATIONS, WATER
 SHALL NOT ACCUMULATE UPON THE SURFACE OF
 THE BENCH AND THE BENCH SHALL HAVE A
 SLIP-RESISTANT SURFACE.
  
 5) PLANS INDICATE THE USE OF POWER
 ACTIVATED AUTOMATIC SLIDING GLASS DOORS,
 PROVIDE COMPLIANCE WITH :
 1012.4 HORIZONTAL SLIDING DOORS.
 APPROVED AND LISTED HORIZONTAL SLIDING
 DOORS COMPLYING WITH THE FOLLOWING
 CONDITIONS MAY BE USED IN A MEANS OF
 EGRESS WHEN SPECIFICALLY PERMITTED BY
 1012.1.2, EXCEPTION 3.
 FOR A BIPARTING SLIDING DOOR IN THE
 EMERGENCY BREAK-OUT MODE, A DOOR LEAF
 LOCATED WITHIN A MULTIPLE-LEAF OPENING
 SHALL BE EXEMPT FROM THE MINIMUM 32 IN.
 (81-CM) SINGLE-LEAF REQUIREMENT OF IF A
 MINIMUM OF 32 IN.(81 CM) CLEAR OPENING
 IS PROVIDED BY ALL LEAFS BROKEN OUT.
  
 6) RESTROOMS: 1204.2 SURROUNDING
 MATERIALS. THE WALLS AND FLOORS OF ALL
 PUBLIC REST ROOMS SHALL BE LINED WITH
 NONABSORBENT MATERIAL TO A HEIGHT OF 4
 FT (1219 MM) ABOVE THE FLOOR.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  