| Notes |
| Date |
Text |
| 2005-07-23 00:00:00 | DENIED; | | | 1.SANITARY RISER DIAGRAM; | | | A.VENT AND WASTE PIPING SYSTEM IS NOT | | | REQUIRED IN A HOSE SYSTEM. | | | B.FIRST FLOOR BATHROOM NOT TIED TO | | | BUILDING DRAIN. | | | C.WASHING MACHINE ON FIRST FLOOR NOT | | | VENTED. | | | D.ALL SANITARY DRAINAGE PIPING SHALL | | | BE SIZED FOR FUTURE FIXTURES,(3" FLOOR | | | DRAIN FOR JACUZZI) | | | E.2-WAY CLEANOUT REQUIRED FOR CABANA | | | 3' OUTSIDE BUILDING. | | | 2.SHOW SIZE OR ROOF SCUPPERS AND | | | MATERIAL USED. ALSO SHOW TOTAL SQUIRE | | | FOOTAGE CAULKS. PER CHAPTER 11 FBC | | | PLUMBING. | | | GAS; | | | 1.SEE "GAS PERMIT APPLICATION | | | REQUIREMENTS" SHEET. COMPLY WITH ITEMS | | | 1, 3, 4, 7, AND 9. | | | 2.ALL FUTURE GAS EQUIPMENT SHOULD BE | | | ADDED TO CAULCULATIONS SO GAS PIPE | | | SIZEDOES NOT CHANGE WHEN EQUIPMENT IS | | | ADDED. | | | 3.IS GENERATOR NAT. GAS IF SO CAULKS | | | SHOULD BE INCLUDED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | | | | | | | |
|