| Date |
Text |
| 2005-08-03 00:00:00 | PLAN REVIEW: |
| | |
| | ITEMS REQUIRED TO SUBMIT PLANS FOR |
| | PERMITTING: |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.PRODUCT APPROVALS WITH QUALITY |
| | ASSURANCE REQUIRED FOR THE FOLLOWING. |
| | ROOFING PRODUCTS, EXTERIOR DOORS, |
| | WINDOWS, IMPACT PROTECTION, LINTELS AND |
| | STRAPS AND TIE-DOWNS. |
| | ALL PRODUCT APPROVALS SUBMITTED SHALL |
| | HAVE THE FOLLOWING STATE PRODUCT |
| | APPROVAL ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 4.SLAB WITH GENERATOR, A/C AND POOL |
| | EQUIPTMENT SHALL BE AT 7'6" NGVD. |
| | |
| | 5.SUBSURFACE EXPLORATION REPORT |
| | RECOMMENDS A 10 MIL VAPOR BARRIER |
| | SYSTEM.PLANS SHOW 6MIL. |
| | |
| | 6.SUBMIT A SPIRAL STAIR DETAIL SHOWING |
| | COMPLIANCE WITH FBC 1007.8.2.1 |
| | |
| | 7.PAGE A-7.1 DOOR AND WINDOW SSCHEDULE |
| | IS MISSING. |
| | |
| | 8.BUILDING SPECIFICATIONS SHOW A TYPE |
| | IV UNPROTECTED BUILDING.ACCORDING TO |
| | TABLE 500 THE MAX. ALLOWABLE HEIGHT WITH |
| | OUT SPRINKLERS IS 2 STORIES. |
| | SHOW HOW COMPLIANCE WITH THIS SECTION |
| | WILL BE MADE. |
| | |
| | 9.SHOW WINDOW AND DOOR PRESSURES IN |
| | ACCORDANCE WITH FBC CHAPTER16. |
| | |
| | NOTE:NEW CODE CYCLE CHANGE STARTS |
| | OCTOBER 1, 2005.APPLICATION FOR |
| | PERMITTING SHOULD BE SUBMITTED BEFORE |
| | THEN TO BE ON THE 2001 FBC. |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |
| | |