| 2006-09-29 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)THE GOVERNING CODE AT THE TIME OF |
| | PERMIT APPLICATION WAS FBC2001, BUT THE |
| | PLANS STATE THAT IT WAS DESIGNED |
| | FBC2004.ASCE7-98 IS REFERENCED, WHICH |
| | IS THE CORRECT ENGINEERING STANDARD FOR |
| | THE 2001 CODE BUT NOT 2004 CODE.DESIGN |
| | INTENT IS NOT CLEAR. |
| | |
| | EITHER REVISE THE PLAN TO REFLECT |
| | FBC2001, OR SUBMIT A NEW PERMIT |
| | APPLICATION AND SUBMIT PLANS IN |
| | COMPLIANCE WITH FBC2004. |
| | |
| | 2.)PROVIDE A CODE SUMMARY; GOVERNING |
| | CODE, BUILDING TYPE FBC6, BUILDING |
| | HEIGHT AND AREA FBC5, OCCUPANCY |
| | CLASSIFICATION FBC3, SPRINKLED OR |
| | UNSPRINKLED. |
| | |
| | 3.)PROVIDE A SITE PLAN AND SHOW THE |
| | ACCESSIBLE ROUTE FBC11-4.1.2(1). |
| | |
| | 4.)SEE FBC11-4.13.6 AND FBC11 FIGURE |
| | 25 REGARDING MANEUVERING CLEARANCE, PULL |
| | SIDE, FOR DOOR 30, MASSAGE ROOM 3. |
| | PLANS SHOW AN OBSTRUCTION (COVERING OF |
| | PIPES); WHERE ARE THE PIPES ON THE WALL? |
| | |
| | |
| | 5.)THE STAIR IS TO HAVE ACCESSIBLE |
| | HANDRAILS, FBC 11-4.9.4, PROVIDE A |
| | DETAIL. |
| | |
| | 6.)PLEASE ADJUST VALUE, ADDITIONAL |
| | WORK SHOWN. |
| | |
| | |
| | |