Plan Review Notes
Plan Review Notes For Permit 05061473
Permit Number 05061473
Review Stop Z
Sequence Number 1
Notes
Date Text
2005-07-22 00:00:007/22/05 ***FAILED***
  
 1) PROPOSED SITE PLAN DOES NOT MATCH
 APPROVAL AT TIME OF INFORMAL SITE PLAN
 REVIEW.
  
 1A) SIZE OF DUMPSTER ENCLOSURE DOES NOT
 MATCH THE DETAIL.DUMPSTER SHALL HAVE A
 MINIMUM OF 12'6" OF CLEAR WIDTH.
  
 1B) DUMPSTER ENCLOSURE IS IN INCORRECT
 LOCATION.I BELIEVE THE LOCATION SHOWN
 INTERFERES WITH AN EXISTING EASEMENT.
 INFORMAL SITE PLAN REVIEW APPROVAL
 SWAPPED THE LOCATION OF THE DUMPSTER AND
 THE LOADING ZONE.
  
 2) ADJUST PARKING DETAIL TO SHOW
 DOUBLE-STRIPING ON BOTH SIDES OF THE
 STANDARD PARKING SPACE.
  
 3) DOUBLE-STRIPING OF PARKING STALL
 SHALL CONSIST OF 1'4" FROM CENTERLINE OF
 4" WHITE STRIPE TO CENTERLINE OF 4"
 WHITE STRIPE.
  
 4) EXTEND PHOTOMETRIC LEVELS TO THE
 PROPERTY LINE.ILLUMINATION SHALL NOT
 EXCEED 1.0 FOOTCANDLES ALONG CONGRESS
 AVENUE PROPERTY LINE.
  
 4) PROVIDE DETAILS OF PARKING AND
 WALKWAY LIGHTING FIXTURES.PARKING LOT
 LIGHTING SHALL NOT EXCEED 30 FEET IN
 HEIGHT.WALKWAY LIGHTING FIXTURES SHALL
 NOT EXCEED 15 FEET IN HEIGHT.
  
 5) NO SURVEY SUBMITTED.
  
 6) NO LANDSCAPE PLANS SUBMITTED.
  
 7) ENSURE THAT ALL PLANS ARE CONSISTENT
 AND REFLECT ALL CHANGES/COMMENTS.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 PLANNER AT (561) 822-1435.


Account Summary | Usage Policy | Privacy Policy