| Date |
Text |
| 2005-07-21 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 BUILDING |
| | FBC-2001 CHAPTER 1 |
| | FBC-2001 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. APPLICATION DESCRIPTION OF PROJECT |
| | STATES NEW WAREHOUSE. PLANS SHOW 2 NEW |
| | WAREHOUSES. PLEASE CLARIFY. SECTION |
| | 104.2.1. |
| | 2. SHT C-1 AN RPZ BACKFLOW IS REQUIRED |
| | FOR EACH BUILDING. SECTION 608.13.2. |
| | 3. SHT C-1 NO WATER SERVICE IS SHOWN TO |
| | BUILDING #2, AND THERE IS NO SANITARY |
| | SEWER SHOWN TO EITHER BUILDING. SECTION |
| | 104.2.1. |
| | 4. SHT A1.1 SCOPE OF WORK INDICATES 2 |
| | TENANTS ONLY, AS ADDITIONAL TENANTS ARE |
| | ADDED, DRINKING FOUNTAINS AND SERVICE |
| | SINKS SHALL BE REQUIRED IN EACH SPACE |
| | PER TABLE 403.1 |
| | 5. SHTS 1A2.0 & 2A2.0 SUBMIT |
| | CALCULATIONS FOR PRIMARY AND SECONDARY |
| | ROOF DRAINS. SHOW AREA OF ROOF AND SHOW |
| | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING |
| | PARAPETS ADDED TO AREA OF ROOF IN |
| | CALCULATIONS. INDICATE TOTAL AREA |
| | DRAINED BY EACH ROOF DRAIN. SUBMIT A |
| | DETAIL OF THE PRIMARY AND SECONDARY ROOF |
| | DRAINS WITH SIZE OF EACH. SECTIONS 1106, |
| | AND 1107. |
| | 6. SHTS 1A6.0 & 2A6.0 SHOW THE FOLLOWING |
| | ACCESSIBLITY REQUIREMENTS: |
| | FOR W/C'S: |
| | A. 11-4.16.2 CLEAR FLOOR SPACE |
| | B. 11-4.16.5 FLUSH CONTROLS |
| | FOR LAVS: |
| | C. 11-4.19.3 CLEAR FLOOR SPACE |
| | D. 11-4.19.5 FAUCETS |
| | FOR DRINK FOUNTAINS: |
| | E. 11-4.15.2 SPOUT HEIGHT |
| | F. 11-4.15.3 SPOUT LOCATION |
| | G. 11-4.15.4 CONTROLS |
| | H. 11-4.15.5 CLEARANCES/CLEAR FLOOR |
| | SPACE. |
| | I. 11-4.1.3(10)(A) PROVISIONS FOR THOSE |
| | WHO HAVE DIFFICULTY BENDING OR STOOPING. |
| | 7. SHTA 1A6.0 & 2A6.0 INDICATE HOW THE |
| | GWB ON THE WALL FINISH WILL SATISFY THE |
| | REQUIREMENT OF SECTION 1204.2, WALLS |
| | SHALL HAVE NONABSORBENT MATERIAL UP TO 4 |
| | FEET. |
| | 8. SHTS P1 & P2 SIGNATURE ON SEAL DOES |
| | NOT MATCH THE LEGAL SIGNATURE ON FILE |
| | FOR THE ENGINEER. FAC 61G1-16.003 & FS |
| | 481.2055. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |