| 2005-10-07 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | **NOTE - NEW PLANS SUBMITTED** |
| | |
| | 1.)FBC104.2.1, INFORMATION ON THE |
| | DRAWINGS IS TO BE SPECIFIC.GENERAL |
| | NOTES 3 AND 6, SHEET A-1.0, SHOULD GIVE |
| | SPECIFIC DESIGN CRITERIA.HANDRAILS AND |
| | GUARDRAILS ARE TO COMPLY WITH |
| | FBC1608.2.1 AND 1608.2.2 RESPECTIVELY. |
| | |
| | 2.)PLEASE PROVIDE AN ORIGINAL SOILS |
| | REPORT.DOCUMENTS PREPARED BY AN |
| | ENGINEER AND SUBMITTED FOR PUBLIC RECORD |
| | ARE TO BE SIGNED, SEALED AND DATED |
| | ORIGINALS.CERTIFICATE OF |
| | AUTHORIZATION REQUIRED ON THE DOCUMENT. |
| | FAC61G15-23.002. |
| | |
| | 3.)A-2.0, WEST DECK PLAN, STATES "NEW |
| | WOOD RAMP AND RAILING SEE DETAIL." |
| | DETAIL NOT PROVIDED.PROVIDE A DETAIL |
| | SHOWING GUARDRAIL AND HANDRAIL IN |
| | COMPLIANCE WITH FBC11-4.8.5 AND |
| | FBC11-4.9.4. |
| | |
| | 4.)SHOW RAMP WIDTH, FBC11-4.8.3. |
| | |
| | 5.)IF THE RAMP CHANGES DIRECTION AT |
| | LANDINGS, THE MINIMUM LANDING SIZE SHALL |
| | BE 60IN X 60IN. |
| | |
| | 6.)WHAT IS THE PAVER AT THE EAST DECK |
| | TO BE USED FOR?SEE FBC11-4.1.2(1). |
| | SHOW ACCESSIBLE ROUTE. |
| | |
| | 7.)PROVIDE A DETAIL FOR THE STAIR |
| | HANDRAIL WHICH SHOWS THE BOTTOM |