| Date |
Text |
| 2005-07-12 00:00:00 | DENIED |
| | |
| | 1) DESIGN CRITERIA ON SHEET 1 IS |
| | INCORRECT. THE BASIC WIND SPEED FOR THE |
| | CITY OF WPB IS 140 MPH (3 SECOND GUST). |
| | SEE FBC FIGURE 1606. |
| | |
| | 2) SSTD-10 CAN NOT BE USED FOR DESIGN IN |
| | AREAS WITH BASIC WIND SPEEDS GREATER |
| | THAN 130 MPH. FBC 1606.1.1. |
| | |
| | 3) THE BUILDING CATEGORY IS II NOT B. |
| | THE EXPOSURE CATEGORY IS B. |
| | SEE ASCE 7-98. |
| | |
| | 4) THE INTERNAL PRESSURE COEFFICENT IS |
| | PLUS OR MINUS 0.18 PER ASCE 7-98. |
| | |
| | 5) REVISE GENERAL NOTE 1 FROM STANDARD |
| | TO FLORIDA BUILDING CODE. |
| | |
| | 6) SPECIFY THE OCCUPANCY TYPE AS |
| | R1,R2,R3 OR R4 AS APPLICABLE. |
| | SEE FBC 311.2. |
| | |
| | 7) SPECIFY THE NUMBER OF UNITS IN THIS |
| | BUILDING. |
| | |
| | 8) SUBMIT ENGINEERING FOR THE NEW |
| | TRUSSES. |
| | |
| | 9) SUBMIT STATE/LOCAL PRODUCT APPROVALS |
| | FOR THE NEW EXTERIOR WINDOWS AND DOORS. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. |
| | |
| | 10) SPECIFY HOW EXTERIOR GLAZING WILL BE |
| | PROTECTED FROM WINDBOURNE DEBRIS. SEE |
| | FBC 1606.1.4 AND 3401.7.2.4. IF NOT |
| | INSTALLING IMPACT RATED WINDOWS, SUBMIT |
| | A STORM PANEL INSTALLATION PLAN FOR THE |
| | BUILDING OFFICIAL TO REVIEW. IF THERE IS |
| | AN EXISTING APPROVED PLAN, SUBMIT A |
| | COPY. |
| | |
| | 11) THE SCOPE OF WORK ON THE PLANS IS |
| | MORE THAN LISTED ON THE APPLICATION. |
| | GIVE ADEQUATE DESCRIPTION OF WORK. |
| | |
| | 12) THE GENERAL DISCRIPTION OF |
| | IMPROVEMENTS WAS LEFT BLANK ON THE NOC. |
| | RE-RECORD NOC WITH THIS REQUIRED |
| | INFORMATION. SEE FS 713.13. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |
| | |
| | |
| | |