| Date |
Text |
| 2005-08-09 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2001 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2001 |
| | |
| | 1.)PLEASE SEE PREVIOUS REQUEST (ITEM |
| | #3) FOR STATE OR LOCAL PRODUCT APPROVALS |
| | FAC9B72.THIS IS REQUIRED IN ADDITION |
| | TO THE NOAS.STATE APPROVALS ARE |
| | AVAILABLE AT WWW.FLORIDABUILDING.ORG; |
| | THE APPLICATION FOR LOCAL PRODUCT |
| | APPROVAL IS ON THE SAME SITE. |
| | |
| | 2.)ON THE GLASS APPROVALS, PLEASE |
| | CIRCLE METHOD OF ATTACHMENT AND GLASS |
| | TYPES/SIZES TO BE INSTALLED.NOT ALL |
| | ARE CODE COMPLIANT. |
| | |
| | 3.)SEE PREVIOUS LIST, ITEM #4.THE |
| | PARAPET WALL 1-A8.1 WAS REVISED TO AN |
| | EIFS SYSTEM, NOA01-0614.17.THIS IS |
| | SMALL MISSILE IMPACT ONLY, SHUTTERS |
| | REQUIRED.REMOVABLE SHUTTERS ON LARGE |
| | COMMERCIAL BUILDINGS REQUIRES APPROVAL |
| | BY THE BUILDING OFFICIAL, SEE ATTACHED |
| | POLICY ITEM #13. |
| | |
| | 3.)THE CIVIL SHEET PREPARED BY SIMMONS |
| | & WHITE (SHEET 2 OF 2) SHOWS THE |
| | EXISTING BUILDING AS 53,368 SF.PLEASE |
| | CLARIFY WHY THIS NUMBER IS DIFFERENT |
| | FROM ID.00, EXISTING BUILDING 41,218 SF. |
| | |
| | 4.)SOME SHEETS HAD CHANGES WITHOUT |
| | CLOUDS.TO EXPEDITE PLAN REVIEW, PLEASE |
| | CLEARLY INDICATE ALL CHANGES TO THE |
| | PLAN AND SUBMIT OLD SHEETS. |
| | |
| | 5.)(NEW COMMENT) THE DIMENSIONS ON LS1 |
| | (A NEW SHEET, DATED 7/20/05) ARE NOT |
| | CLEAR AS TO WHAT THEY CORRELATE WITH. |
| | FOR INSTANCE, THE FARTHEST DISTANCE |
| | (EXISTING SERVICE MANAGER) TO THE EXIT |
| | HAS TWO DIMENSIONS, 175' AND 198'. |
| | NEITHER APPEARS TO BE THE CORRECT |
| | DISTANCE. THE COMMON PATH OF TRAVEL |
| | APPEARS TO BE 160' WHEN SCALED; CANNOT |
| | EXCEED 100' FBC1020.6.PLEASE REVISE |
| | THE LS TO CLEARLY SHOW CODE COMPLIANCE. |
| | |
| | 6.)WHEN RESUBMITTING, CHANGE ONLY |
| | SHEETS WHICH HAVE BEEN REVISED.OLD |
| | SHEETS SUBMITTED SEPARATELY.ALL |
| | CHANGES SHOULD BE CLOUDED. |