| 2005-07-11 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)IMPACT FEES ARE DUE TO PALM BEACH | | | COUNTY.THE PLANS MUST BE STAMPED AND | | | THE RECEIPT ATTACHED TO THE APPLICATION. | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVALS REQUIRED FOR: | | | | | | IMPACT STOREFRONT SYSTEM | | | ROOF | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED AND | | | REVIEWED FOR CODE COMPLIANCE PRIOR TO | | | ISSUANCE OF THE PERMIT WILL REQUIRE | | | SEPARATE PERMITS FOR THOSE ITEMS. | | | | | | 4.)FBC606, TYPE IV TO BE NON | | | COMBUSTIBLE WALLS.FBC TABLE 600, | | | FOOTNOTE (E) ALLOWS FIRE TREATED PLYWOOD | | | FOR THE ROOF BUT DOES NOT HAVE THE SAME | | | EXCEPTION FOR WALLS.THE PARAPET WALL | | | 1-A8.1 SHOWS FIRE TREATED PLYWOOD (OTHER | | | DETAILS MAY ALSO BE AFFECTED). | | | | | | 5.)1-A8.1, STUCCO OVER WIRE LATH IN A | | | VERTICAL APPLICATION TO BE 7/8", | | | FBC2504.2.2, ASTM C926. | | | | | | 6.)ID.00 SHOWS THE ADDITION AS 1905 | | | SQUARE FEEET; 1885 IS ON THE ENERGY | | | CALC. | | | | | | 7.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | |
|