2005-07-11 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)IMPACT FEES ARE DUE TO PALM BEACH
 COUNTY.THE PLANS MUST BE STAMPED AND
 THE RECEIPT ATTACHED TO THE APPLICATION.
 561-233-5025 FOR MORE INFORMATION.
  
 2.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 3.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVALS REQUIRED FOR:
  
 IMPACT STOREFRONT SYSTEM
 ROOF
  
 ANY PRODUCT APPROVALS NOT SUBMITTED AND
 REVIEWED FOR CODE COMPLIANCE PRIOR TO
 ISSUANCE OF THE PERMIT WILL REQUIRE
 SEPARATE PERMITS FOR THOSE ITEMS.
  
 4.)FBC606, TYPE IV TO BE NON
 COMBUSTIBLE WALLS.FBC TABLE 600,
 FOOTNOTE (E) ALLOWS FIRE TREATED PLYWOOD
 FOR THE ROOF BUT DOES NOT HAVE THE SAME
 EXCEPTION FOR WALLS.THE PARAPET WALL
 1-A8.1 SHOWS FIRE TREATED PLYWOOD (OTHER
 DETAILS MAY ALSO BE AFFECTED).
  
 5.)1-A8.1, STUCCO OVER WIRE LATH IN A
 VERTICAL APPLICATION TO BE 7/8",
 FBC2504.2.2, ASTM C926.
  
 6.)ID.00 SHOWS THE ADDITION AS 1905
 SQUARE FEEET; 1885 IS ON THE ENERGY
 CALC.
  
 7.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  