| Plan Review Notes For Permit 05060670 |
| Permit Number |
05060670 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-07-20 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | | 2- NEED WORST CASE SCENARIO ENERGY CALCS | | | 3- CLARIFY DOOR/WINDOW SCHEDULE. DON'T | | | MIX TOGETHER DOOR/WINDOW SYMBOLS USED. | | | 4- REVISE DETAIL 5/D1: CONNECTOR HTS20 | | | CAN'T SUPPORT BEAM. | | | 5- TRUSS ANCHOR SCHEDULE: UPDATE HUS26 | | | NAIL SIZE. SEE LATEST CATALOGUE. | | | 6- ROOF FRAMING PLAN: REVISE CONNECTOR | | | SPECIFIED AT ENTRY PORCH TO MATCH | | | DETAILS 5/D1 AND 6/D1. | | | 7- RE-SUBMIT PRODUCT APPROVAL FOR: | | | A) ROOF TILE. | | | B) SINGLE HUNG WINDOWS. | | | C) FIXED WINDOWS. | | | 8- SHEET A-5 SHEAR VALUES NOTE: PROVIDE | | | HAND CALCULATIONS. WHY USING TIMBER | | | CONSTRUCTION MANUAL FOR TAPCONS VALUES? |
|