| Plan Review Notes For Permit 05060653 |
| Permit Number |
05060653 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-08-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT S-6 NOT APPROVED. NO GLUED/PASTED | | | SHEETS ALLOWED ON SIGNED/SEALED PLANS. | | | SECTION 104.2.1.3. | | | 2. SHT S-6 THE WASH MACHINE SHALL | | | CONNECT TO THE GREASE DRAIN DOWNSTREAM | | | OF THE TRAP OF THE TRENCH DRAIN. SECTION | | | 1002.1. | | | 3. SHT S-6 WATER HAMMER ARRESTORS ARE | | | REQUIRED AT THE WASH MACHINE. SECTION | | | 604.9 | | | 4. SHT S-6 SHUT OFF VALVES ARE REQUIRED | | | ON THE WATER SUPPLY PIPE TO EACH HOSE | | | BIBB. SECTION 606.2(2). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|