2005-08-18 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE TOTAL RISE SHOWN ON BSP1 IS 36"
 WITH FIVE RISERS, EACH INDIVIDUAL RISER
 WOULD BE 7.2" WHICH EXCEEDS THE 7"
 MAXIMUM FBC1007.3.1. THIS IS IN CONFLICT
 WITH D-SP1 WHICH SHOWS 7" RISERS.
  
 2.)THE HANDRAIL FOR THE STAIRS IS TO
 BE ROUNDED OR RETURNED SMOOTHLY TO THE
 FLOOR, FBC11-4.9.4(6).SEE FIGURE 11-19
 FOR AN EXAMPLE.
  
 3.)FROM PREVIOUS LIST, SECTION B-SP1
 SHOWS ONE RAIL, D-SP1 (PLAN) APPEARS TO
 SHOW TWO (GUARDRAIL AND HANDRAIL).
 PLEASE CLARIFY WITH CODE COMPLIANT
 DETAILS. TO FURTHER CLARIFY THE PREVIOUS
 COMMENT, PLEASE PROVIDE A DETAIL FOR THE
 GUARDRAIL IN COMPLIANCE WITH FBC1015.
 THE PLAN APPEARS TO SHOW ONE BUT NO
 DETAIL IS PROVIDED.
  
 4.)A GUARDRAIL IS REQUIRED AT THE
 RAMP AND DECK FBC1015.PLEASE PROVIDE
 DETAILS.