| Date |
Text |
| 2005-07-05 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT:05060152 |
| | ADD:2001 FLORIDA AVE |
| | CONT:FRED BLACK AND ASSO. |
| | TEL: (561)309-7638 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) PLEASE REVISED APPLICATION TO SHOW |
| | THE CORRECT SCOPE OF WORK ON THIS |
| | PROJECT.THERE IS NO MENTION OF INTERIOR |
| | WORK ON THE APPLICATION,HOWEVER THE |
| | PLANS SHOWS REVISION OF VARIOUS SECTIONS |
| | OF THE INTERIOR WALLS. |
| | |
| | 2) EACH SHEET OF PLANS SHALL BE |
| | SEALED/SIGNED/DATED AND LEGIBLY INDICATE |
| | THEIR NAME/ADDRESS AND LICENSE NUMBER ON |
| | EACH SHEET. THE SEAL ON THE PLANS ARE |
| | NOT ACCEPTABLE. SEE F.A.C.61G15-23.002 |
| | AND CH 471,F.S. |
| | |
| | 3) SUBMIT PRODUCT APPROVAL FOR THE FLAT |
| | ROOF/ROOF TILES AND NEW GARAGE DOOR. |
| | |
| | PLEASE READ THIS NOTE CAREFULLY |
| | 4) FBC 1606.2.5THE SYSTEM SELECTED |
| | FROM THE SUBMITTED FLAT ROOF PRODUCT |
| | APPROVAL NOA HAS A MAXIMUM DESIGN |
| | PRESSURE OF LESS THAN -89 PSF AND CITES |
| | GENERAL LIMITATION #9.GENERAL |
| | LIMITATION #9 PROHIBITS RATIONAL |
| | ANALYSIS OR EXTRAPOLATION TO ENHANCE THE |
| | UPLIFT PRESSURE AT PERIMETER AND CORNER |
| | AREAS BY REDUCING THE FASTENER SPACING |
| | IN THESE AREAS.EITHER SELECT AN |
| | ALTERNATIVE SYSTEM (OR PRODUCT APPROVAL) |
| | THAT DOES NOT CITE GENERAL LIMITATION |
| | #9.ALTERNATIVELY IF THE SELECTED |
| | SYSTEM DOES CITE GENERAL LIMITATION #9, |
| | IT MUST HAVE A MAXIMUM DESIGN PRESSURE |
| | THAT EXCEEDS THE PRESSURE IN ROOF ZONE 3 |
| | (TYPICALLY -89 PSF FOR MEAN ROOF HEIGHT |
| | OF 30 FEET OR LESS). |
| | |
| | 5)A SEPERATE PERMIT IS REQUIRED FOR THE |
| | NEW PRIVACY FENCE. |
| | |
| | 6) IF THE FLAT ROOF IS ENCLOSE WITH THE |
| | PARAPET, PLEASE SHOW REQUIRED DRAINAGE. |
| | |
| | 7) 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | BUILDING PLAN REVIEW |
| | MYRON JACOBS |
| | TEL: (561)805-6726 |
| | FAX: (561)659-8026 |