Plan Review Notes
Plan Review Notes For Permit 05060152
Permit Number 05060152
Review Stop B
Sequence Number 1
Notes
Date Text
2005-07-05 00:00:00BUILDING PLAN REVIEW
 PERMIT:05060152
 ADD:2001 FLORIDA AVE
 CONT:FRED BLACK AND ASSO.
 TEL: (561)309-7638
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) PLEASE REVISED APPLICATION TO SHOW
 THE CORRECT SCOPE OF WORK ON THIS
 PROJECT.THERE IS NO MENTION OF INTERIOR
 WORK ON THE APPLICATION,HOWEVER THE
 PLANS SHOWS REVISION OF VARIOUS SECTIONS
 OF THE INTERIOR WALLS.
  
 2) EACH SHEET OF PLANS SHALL BE
 SEALED/SIGNED/DATED AND LEGIBLY INDICATE
 THEIR NAME/ADDRESS AND LICENSE NUMBER ON
 EACH SHEET. THE SEAL ON THE PLANS ARE
 NOT ACCEPTABLE. SEE F.A.C.61G15-23.002
 AND CH 471,F.S.
  
 3) SUBMIT PRODUCT APPROVAL FOR THE FLAT
 ROOF/ROOF TILES AND NEW GARAGE DOOR.
  
 PLEASE READ THIS NOTE CAREFULLY
 4) FBC 1606.2.5THE SYSTEM SELECTED
 FROM THE SUBMITTED FLAT ROOF PRODUCT
 APPROVAL NOA HAS A MAXIMUM DESIGN
 PRESSURE OF LESS THAN -89 PSF AND CITES
 GENERAL LIMITATION #9.GENERAL
 LIMITATION #9 PROHIBITS RATIONAL
 ANALYSIS OR EXTRAPOLATION TO ENHANCE THE
 UPLIFT PRESSURE AT PERIMETER AND CORNER
 AREAS BY REDUCING THE FASTENER SPACING
 IN THESE AREAS.EITHER SELECT AN
 ALTERNATIVE SYSTEM (OR PRODUCT APPROVAL)
 THAT DOES NOT CITE GENERAL LIMITATION
 #9.ALTERNATIVELY IF THE SELECTED
 SYSTEM DOES CITE GENERAL LIMITATION #9,
 IT MUST HAVE A MAXIMUM DESIGN PRESSURE
 THAT EXCEEDS THE PRESSURE IN ROOF ZONE 3
 (TYPICALLY -89 PSF FOR MEAN ROOF HEIGHT
 OF 30 FEET OR LESS).
  
 5)A SEPERATE PERMIT IS REQUIRED FOR THE
 NEW PRIVACY FENCE.
  
 6) IF THE FLAT ROOF IS ENCLOSE WITH THE
 PARAPET, PLEASE SHOW REQUIRED DRAINAGE.
  
 7) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026